Chapter 10
2) Remove the E-ring[1] and the bushing [2] at the
front; then, remove the gear [3] and the bushing
[4] at the rear.
F-10-148
3) Free the internal delivery roller [1] from the cut-
off of the frame at the front; then, remove it.
F-10-149
10-66
10.10.30 Fixing/Feeder Unit Open/
Closed Sensor
10.10.30.1 Preparation for Removing the
Fixing/Feeder Unit Open/Closed
Sensor
1) Remove the upper left cover. (page 12-
23)Reference[Removing the Upper Left Cover]
2) Remove the center delivery tray [2].
- 2 screws [1]
F-10-150
3) Remove the delivery vertical path unit (New).
(page 10-93)Reference[Removing the Delivery
Vertical Path Unit]
4) Remove the fixing/feeder unit open/closed sensor
mounting plate.
Before removing the fixing/feeder unit, be sure to
mark its position using a scriber.
F-10-151