Chapter 5
5.4.8.3 Mounting the Scanner Motor
iR5065 / iR 5055 / iR5075 / / /
When mounting the scanner motor, check to make sure that the timing belt
[3] is properly fitted to the scanner pulley [1] and the motor shaft [2].
[3]
[2]
5.4.9 ADF Open/Close Sensor
5.4.9.1 Before Removing the ADF Open/Close Sensor
iR5065 / iR 5055 / iR5075 / / /
1) Detach the reader rear cover. (page 10-16)Reference[Detaching the
Reader Rear Cover]
5.4.9.2 Removing the ADF Open/Close Sensor
iR5065 / iR 5055 / iR5075 / / /
1) Disconnect the connector [1].
[2]
2) Detach the reinforcing plate [2].
- 4 Screw [1]
5-22
[1]
F-5-69
[3]
F-5-70
[1]
F-5-71
0015-4837
3) Detach the ADF open/close sensor (1, 2).
- Hook [1]
5.4.10 Scanner HP Sensor
0015-4838
5.4.10.1 Before Removing the Scanner HP Sensor
iR5065 / iR 5055 / iR5075 / / /
1) Detach the ADF.
2) Detach the reader rear cover. (page 10-16)Reference[Detaching the
Reader Rear Cover]
0015-4839
5.4.10.2 Removing the Mirror Base HP Sensor
iR5065 / iR 5055 / iR5075 / / /
1) Detach the reinforcing plate [2].
- 4 Screw [1]
2) Detach the sensor base [2].
- 1 Screw [1]
[1]
[1]
F-5-72
[1]
F-5-73
[1]
[1]
F-5-74
[2]
[1]
0015-4840
0015-4841
[2]