Chapter 10
10.10.56 Delivery Vertical Path Cover
Open/Closed Sensor
10.10.56.1 Preparation for Removing the
Delivery Vertical Path Cover Open/
Closed Sensor
1) Remove the upper left cover. (page 12-
23)Reference[Removing the Upper Left Cover]
2) Remove the center delivery tray [2].
(Referring to procedure 10.10.54)
3) Remove the delivery vertical path unit. (page 10-
93)Reference[Removing the Delivery Vertical
Path Unit]
10.10.56.2 Removing the Delivery Vertical
Path Cover Open/Closed Sensor
1) Remove the crossmember [1].
- 1 Screw [2]
[1]
F-10-293
2) Remove the delivery vertical path cover open/
closed sensor [2].
- 1 connector [1]
[1]
F-10-294
10-106
[2]
[2]
10.10.57 Delivery Path Switching
Solenoid 1
10.10.57.1 Preparation for Removing the
Delivery Path Switching Solenoid 1
1) Remove the upper left cover. (page 12-
23)Reference[Removing the Upper Left Cover]
2) Remove the center delivery tray [2].
(Referring to procedure 10.10.54)
3) Remove the delivery vertical path unit. (page 10-
93)Reference[Removing the Delivery Vertical
Path Unit]
4) Remove the cleaner fan cover.
5) Remove the cleaner fan [2].(page
59)Reference[Removing the Cleaner Fan]
Leave the 2 screws as they are, and disconnect the
cable from the guide around the fan.
10.10.57.2 Removing the Delivery Path
Switching Solenoid 1
1) Remove the delivery path switching solenoid 1
[3].
- 1 connector [1]
- 1 screw [2]
F-10-295
10.10.58 Delivery Path Switching
Solenoid 2
10.10.58.1 Preparation for Removing the
Delivery Path Switching Solenoid 2
1) Remove the fixing unit.
1-1) Remove the fixing drive unit.(page 11-
38)Reference[Removing the Fixing Drive
Unit]
1-2) Remove the fixing unit.
2) Remove the fixing/feeder unit.(page 10-
63)Reference[Removing the Fixing/Feeder Unit]
12-