Chapter 10
2) Remove the duplex feeder motor [2].
- Screws[1]2
[1]
F-10-207
Points to Note When Attaching the Duplex
Feed Motor
(1) Be sure that the connector area is at the bottom.
(2) When mounting the motor, check to be sure that
the belt [2] is hooked on to the gear [1].
[1]
F-10-208
10-82

10.10.41 Duplex Registration Sensor

10.10.41.1 Preparation for Removing the
Duplex Registration Sensor
1) Remove the fixing unit.
1-1) Remove the fixing drive unit.(page 11-
38)Reference[Removing the Fixing Drive
Unit]
1-2) Remove the fixing unit.
[1]
2) Remove the fixing/feeder unit.(page 10-
63)Reference[Removing the Fixing/Feeder Unit]
3) Remove the fixing/feeder assembly back sheet.
[2]
- When placing the fixing feeder unit upright, be sure
to use paper to prevent dirt from collecting.
- If you forgot to use paper, make a double-sided test
copy before ending the work.
[2]
3-1) Stand it so that the fixing feeder unit cover is at
the bottom.
F-10-209