Chapter 6
4) ADF Cover Fully Closed (5 deg or less).
The machine checks for a change in the output levels of the sensors for 2 sec after the ADF open/closed sensor
has identified the ADF as being "closed"; the machine assumes the absence of an original at points without
a change.
The machine then identifies the size of the original based on the combination of changes at 5 points.
5) Standby (in wait for a press on the Start key)
No. 1 mirror base: at point of original detection
xenon lamp: off
original sensor: off
AB-Configuration
Point of CCD
Original
detection
1
size
A B
A3
B4
A4R
A4
B5
B5R
A5
B6
absent
6-16
Original
2
3
4
A B
A B
A B
sensor 1
25
F-6-23
5
F-6-24
F-6-25
Inch-configuration
Original
size
11"x17"
LGL
LTRR
LTR
STMTR
STMT
absent
:unchanged
F-6-26
Point of CCD
detection
Original
1
2
3
sensor 3
A B
A B
A B
:changed