6.4.10 Original Sensor

6.4.10.1 Preparation for Removing the
Original Size Sensor
1) Remove the Copyboard Glass.
2) Remove the CCD unit cover [2].
(Referring to Procedure 6.4.6)
3) Remove the Original Size Sensor Unit.
3-1) Remove the original size detection unit [2].
- 3 screws [1]
F-6-66
3-2) Remove the original size sensor unit [2].
- connector [1]
1]
F-6-67
[1]
[2]
[1]
2]
6.4.10.2 Removing the Original Size
Sensor
1) While removing the claw at the edge, remove the
original size sensor [1].
[1]
F-6-68

6.4.11 Cooling Fan

6.4.11.1 Preparation for Removing the
Cooling Fan
1) Remove the Reader Rear Cover.
6.4.11.2 Removing the Cooling Fan
1) Remove the cooling fan [4].
- 1 connector [2] (open the wire guide [1], and
remove the cable)
- 2 screws [3]
[2]
[1]
F-6-69
Chapter 6
[3]
[4]
6-33