Error Code Details - Canon imagerunner C5180 Service Manual

Hide thumbs Also See for imagerunner C5180:
Table of Contents

Advertisement

Chapter 18

18.2 Error Code Details

18.2.1 Table of error code details
Displayed
Detection timing
code
E000
Insufficient temperature rise of fixing unit when power is turned ON
0001 When the temperature of the fixing
belt main thermistor failed to reach
50 deg C within 120 sec. after the
fixing belt temperature regulation
has started
0101 When the temperature of the
pressure belt main thermistor failed
to reach 50 deg C within 120 sec.
after the pressure belt temperature
regulation has started
E001
Abnormally high temperature rise of fixing unit (circuit trouble)
0001 When the fixing belt main
thermistor has detected a high
temperature (ASIC detection)
0002 When fixing sub-thermistor 1 has
detected a high temperature (ASIC
detection)
0003 When fixing sub-thermistor 2 has
detected a high temperature (ASIC
detection)
0101 When pressure main thermistor has
detected a high temperature (ASIC
detection)
0102 When pressure sub-thermistor 1 has
detected a high temperature (ASIC
detection)
0103 When pressure sub-thermistor 2 has
detected a high temperature (ASIC
detection)
E002
Insufficient temperature rise of fixing unit
18-4
T-18-2
Remedial action
Check for broken or disconnected heater wires.
Checking Disconnection of the Connector in the Thermistor Wiring.
Replace the fixing belt unit. Replace the fixer. Replace the IH power supply
PCB and AC driver PCB. Replace the DC controller PCB 2 (MAISY).
In the service mode, clear the error by selecting COPIER > FUNCTION >
CLEAR > ERR.
Check for broken or disconnected heater wires. Replace the fixing belt unit.
Checking Disconnection of the Connector in the Thermistor Wiring.
Replace the fixer and AC driver PCB. Replace the DC controller PCB 2
(MAISY).
In the service mode, clear the error by selecting COPIER > FUNCTION >
CLEAR > ERR.
Check the connection of the connector in the thermistor wiring (wire-
pinching, disconnection).
Replace the fixing unit. Replace the IH unit, halogen heater, fixer and AC
driver PCB. Replace the DC controller PCB 2 (MAISY).
In the service mode, clear the error by selecting COPIER > FUNCTION >
CLEAR > ERR.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Imagerunner c4080Imagerunner c4580

Table of Contents