COMP-PRT Composite print operation control (image processing memory allocation control)
When a count of 2 or more prints are to be made in page print/ set print/ stamp/ date print/ book
binding/ watermark print (composite print), depending on the memory model (optional configuration)
and document size, the memory allocation method is set to 'print priority' for image processing
purposes. This means there is not enough memory for image processing for Scan, Send Tx (excluding
FAX) and PDL entry, and these operations must wait until printing is finished.
In this case, all memory is allocated equally to all jobs so that the operations can be carried out (each
a little at a time) without waiting until printing is finished.
Setting values
0: Print priority
1: Equal allocation
[Factory settings and after RAM clear: 0]
FX-ST-SP
Fixing unit idling speed in standby.
Sets the fixing unit idling speed in standby.
Setting values
0: 32 mm/s
1: 50 mm/s
2: 70 mm/s
[Factory settings and after RAM clear: 0]
FIX-RT-T
Change intermission interval in standby
Sets rotation stop interval in standby.
Setting range: 0 to 300 (in units of 10 sec.)
[Factory settings and after RAM clear: 0]
DELV-THC Switch toner ejection threshold value (C)
Sets threshold value of mean image ratio for forced toner ejection sequence.
Setting range: 1 to 5(%)
[Factory settings and after RAM clear: 2]
DELV-
Switch toner ejection threshold value (M)
THM
Sets threshold value of mean image ratio for forced toner ejection sequence.
Setting range: 1 to 5(%)
[Factory settings and after RAM clear: 2]
DELV-THK Switch toner ejection threshold value (Bk)
Sets threshold value of mean image ratio for forced toner ejection sequence.
Setting range: 1 to 5(%)
[Factory settings and after RAM clear: 2]
FX-EX-TM Extend warm-up time
Sets warm-up time.
Setting values
0: default
1: 1 min. extension
2: 2 min extension
[Factory settings and after RAM clear: 0]
FAN-SLP
Switch fan sequence when entering sleep mode.
Setting range
0: Sequence uses environment sensor temperature reading.
1: Sequence does not use environment sensor temperature reading.
[Factory settings and after RAM clear: 0]
AST-SEL
Change advanced smoothing range
Used when adjustments to advanced smoothing effect are felt necessary.
If the smoothing effect is felt to be too strong, even though 'Soft' is selected in the advanced smoothing
UI, set this item to '0'. If the smoothing effect is felt to be too weak, even though 'Strong' is selected
in the advanced smoothing UI, set this item to '3'.
Setting range: 0 to 3
[Factory settings and after RAM clear: 2]
COPIER>OPTION>BODY
Chapter 19
2
2
2
2
2
2
2
2
2