Chapter 19
Sub item
STRD-POS
Use it to adjust the CCD read position for DF stream reading mode.
Method of Adjustment
- an increase by '1' will move the image read position to the left by 1 mm.
- if you have initialized the RAM on the reader controller PCB or replaced the reader controller PCB,
enter the value indicated on the service label.
Range of Adjustment 1 to 200 [Factory default/After RAM clear: 110]
Attention
If you have changed the setting, be sure to record the new setting on the service label.
Vertical size plate
White plate
Decreasing setting value
(read start position moves
in direction of leading edge)
19-40
COPIER>ADJUST>ADJ-XY
Image's leading
edge
Decreasing setting value
(read start position moves
away from you)
Increasing setting value
(read start position
moves toward you)