Canon imagerunner C5180 Service Manual page 624

Hide thumbs Also See for imagerunner C5180:
Table of Contents

Advertisement

Chapter 18
Displayed
Detection timing
code
0201 When the difference in temperature
between the front and back of the
fixing belt is higher than the rating
0202 When the difference in temperature
between the center and front of the
fixing belt is higher than the rating
0203 When the difference in temperature
between the center and back of the
fixing belt is higher than the rating
0204 When the difference in temperature
between the front and back of the
pressure belt is higher than the
rating
0205 Thermistor temperature difference
error (combination unknown)
0301 When an overcurrent has been
detected in the IH power supply
PCB
0401 13 V trouble error
0501 Fixing main thermistor or fixing
sub-thermistor 1 or 2 connection
error
0502 Pressure main thermistor or
pressure sub-thermistor 1 or 2
connection error
0601 IH power supply ID error
0701 Relay OFF status error
E007
Fixing belt or pressure belt deviation trouble
0001 Fixing belt deviation trouble
(trouble in top belt displacement or
in belt deviation sensor)
0002 Pressure belt deviation trouble
(trouble in bottom belt push-off or
in belt deviation sensor)
0101 Fixing belt home position detection
error
0102 Pressure belt home position
detection error
0201 Belt push-off temporary escape
mode error
9991 Top belt deviation control timeout
error
9992 Bottom belt deviation control
timeout error
E008
Fixing unit end-of-life detection error
18-6
Remedial action
Replace the fixing belt unit. Replace the DC controller PCB 2 (MAISY).
Replace the IH power supply PCB. Replace the fixing belt unit.
Check the connection of the connectors of the relay PCB, the IH power
supply, the fixing thermoswitch, and replace the fixing unit (fixing
thermoswitch OFF), the relay PCB, and the IH power PCB (blowout of the
FU261).
In the service mode, clear the error by selecting COPIER > FUNCTION >
CLEAR > ERR.
Check the connections of the fixing belt unit connectors. Replace the fixing
belt unit.
Check the connections of the pressure belt unit connectors. Replace the
pressure belt unit.
Check the connection of the connectors of the IH power supply PCB J1009,
the DC controller PCB 2 (MAISY) J109, and the relay PCB connector.
In the case of not being locked after turning ON the motor
Replace the relay PCB.
Replace the fixing unit.
Replace the fixing unit.
Replace the fixing belt HP sensor. Replace the fixing deviation control
motor, DC controller PCB 2 (MAISY) and fixing unit.
Replace the pressure belt HP sensor. Replace the pressure deviation control
motor, DC controller PCB 2 (MAISY) and fixing unit.
Occurs when the belt deviation is not eliminated within 1 minute in the belt
push-off temporary escape mode.
Occurs when operation was not performed normally when COPIER >
FUNCTION > FIXING > FX-UHP-S was executed.
Occurs when operation was not performed normally when COPIER >
FUNCTION > FIXING > FX-LHP-S was executed.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Imagerunner c4080Imagerunner c4580

Table of Contents