3-2) Remove the sheet [1] from behind the fixing
feeder assembly.
- 6 snap-ons [A]
- 3 hooks [B]
[A]
[1]
F-10-210
10.10.41.2 Removing the Duplex
Registration Sensor
1) Remove the duplex registration sensor [4].
- connector [1]
- 2 claws [2]
- sensor base [3]
F-10-211
[A]
[B]
10.10.42 Duplex Horizontal
Registration Sensor
10.10.42.1 Preparation for Removing the

Duplex Horizontal Registration Sensor

1) Remove the fixing unit.
1-1) Remove the fixing drive unit.(page 11-
38)Reference[Removing the Fixing Drive
Unit]
1-2) Remove the fixing unit.
2) Remove the fixing/feeder unit.(page 10-
63)Reference[Removing the Fixing/Feeder Unit]
3) Remove the fixing/feeder assembly back sheet.
- When placing the fixing feeder unit upright, be sure
to use paper to prevent dirt from collecting.
- If you forgot to use paper, make a double-sided test
copy before ending the work.
F-10-212
3-1) Stand it so that the fixing feeder unit cover is at
the bottom.
Chapter 10
10-83