Points to Note When Attaching the Auto
Registration Sensor PCB
When Attaching the plate [1], be sure that its edge is
farther on the inner side than the cleaning member
[2].
F-9-142

9.9.20 SALT Sensor

9.9.20.1 Preparation for Removing the
SALT Sensor
1) Slide out the manual feed unit.
2) Removing the intermediate transfer unit. (page 9-
60)Reference[Removing
Transfer Unit]
3) Remove the upper right cover. (page 12-
20)Reference[Removing the Upper Right Cover]
4) Remove the pattern reader unit. (page 9-
79)Reference[Removing the Pattern Reader Unit]
the
Intermediate
9.9.20.2 Removing the SALT Sensor
1) Remove the plate from the rear of the pattern
reader unit [2].
- 3 screws [1]
F-9-143
2) Remove the SALT sensor [3].
- 2 screws [1]
- 1 connector [2]
F-9-144