DDR Interposer
1.5.2

Kibra 380 or Kibra 480 Slot 2 Interposer

Interactions among up to 8 ranks over two slots are analyzed. 
The Kibra 380 Slot 2 Interposer is shown below. Do not leave the second interposer 
connected if it is not probing a DIMM on the HUT. Leaving it unconnected will cause 
some signals to float, causing false errors to be reported in the trace.
Figure 1.7: Slot 2 Interposer
1.5.3

External Trigger Out

Pulse Width = 280 ns 
Pulse Voltage = 3.3 Volts into 1 MegOhms
Pulse Voltage = 2.7 Volts into 50 Ohms
Pulse is positive going.
Accumulated Latency from DDR Event to Pulse out at SMA terminal:
DIMM_CLK=400MHz   125 ns 
DIMM_CLK=533MHz   105 ns
DIMM_CLK=667MHz   105 ns
DIMM_CLK=800MHz   100 ns
All measurements are  10 ns
       
K ibra DDR Protocol Analyzer User Manual
 Teledyne LeCroy
19