DOOR CONTROL
Control Cable Adjustment
When disconnecting the control cable, remove the E-ring
and take off the cable while pushing the cable outer in the
direction of the arrow.
AIR CONTROL CABLE
Clamp the cable while pushing cable outer and side link in
direction of arrow.
After positioning control cable, check it operates properly.
WATER COCK CONTROL ROD
When adjusting water cock control rod, first disconnect
temperature control cable from air mix door lever. Re-
connect and readjust temperature control cable.
1. Push air mix door lever in direction of arrow.
2. Pull control rod of water cock in direction of arrow so as to
make clearance of about 2 mm (0.08 in) between ends of
rod and link lever and connect the rod to door lever.
After connecting control rod, check it operates properly.
TEMPERATURE CONTROL CABLE
Clamp the cable while pushing cable outer and air mix door
lever in direction of arrow.
After positioning control cable, check it operates properly.

Advertisement