Ford Corsar Repair Manual page 287

Table of Contents

Advertisement

7
TROUBLE DIAGNOSES
piEiq
Self-diagnosis
-
Mode
I1
(Exhaust gas sensor
monitor)
DESCRIPTION
In this mode, the E.C.M.
LIGHT
and
RED L.E.D.
display the condition
of the fuel mixture (lean
o r rich) w h i c h i s monitored by
the
exhaust
qas sensor.
I
E.C.M.
LIGHT and RED L.E.D.
Fuel mixture condition in the exhaust
Air fuel ratio feedback control condition
gas
I
ON
OFF
HOW TO CHECK EXHAUST GAS SENSOR
1.
Set Mode
II.
(Refer to "HOW TO SWITCH MODES".)
2.
Start engine and warm it up until engine coolant tempera-
ture indicator points to the middle of the gauge.
3.
Run engine at about 2,000 rpm for about 2 minutes under
no-load conditions.
4.
Make sure
RED L.E.D.
or E.C.M.
LIGHT
goes ON and OFF more than
5 times every 10 seconds; nleasured at 2,000 rpm under no-load.
I
-
Lean
Rich
"Remains ON or OFF
Closed loop control
I
*: Maintains conditions just before switching to open loop.
Any condition
Open loop control