Of4-001 Main Motor Rap - Xerox DocuColor 12/DCCS50 Service Manual

Table of Contents

Advertisement

OF4-001 Main Motor RAP

This RAP is used to repair the Main Motor and Drum Motor circuit failures when directed by
another RAP.
Initial Actions
Refer to BSD 4.1, Main and Drum Drive Control, in the following procedure:
Check the Drive Mechanism for damage, jams, and obstructions.
Procedure
Go to
Flag 1
BSD 4.1 and check for +5 VDC at P/J42-14 on the Distribution PWB. +5 VDC is
measured at P/J42-14 on the Distribution PWB.
Y
N
Perform the following:
Go to
Flag 1
BSD 4.1 and check for a short/open circuit.
Go to the
+5 VDC Power (IOT LVPS)
Perform the following:
Enter DC330 004-007 Main Motor, Press Start and Stop.
Check for a change of state from (L) to +5 VDC at P/J417B-5 on the IOT Drive PWB.
The voltage at P/J417B-5 switched between (L) and +5 VDC at P/J417B-5 on the IOT
Drive PWB.
Y
N
Perform the following:
Go to
Flag 3
on BSD 4.1 and check for an open/short circuit.
Replace the Main Motor
(PL
1.2).
Replace the IOT Drive PWB
(PL
Go to
Flag 2
on BSD 4.1 and check for +24 VDC at P/J42-11 and 12, on the Distribution PWB.
+24 VDC is measured at
P/J42
-11 and 12, on the Distribution PWB.
Y
N
Perform the following:
Go to
Flag 2
on BSD 4.1 check for an open/short circuit.
Go to the
+24 VDC Power (IOT LVPS)
Enter DC330 004-007 Main Motor. Press Start. The Main Motor runs.
Y
N
Check for Logic (L) at P/J417B-5. Logic (L) is measured at P/J417B-5.
Y
N
Perform the following:
Go to on
Flag 4
BSD 4.1 and check for an open/short circuit.
Replace the Main Motor
(PL
Replace the IOT Drive PWB
Perform the following:
While exercising [04-021] in Component Control, check for a change of state on the
Main Motor On line P/J417B-5.
While in [04-021] Component Control and the Main Motor is running, check for the
following conditions at
A
Reissue
DocuColor 12/DCCS50
RAP.
9.2).
RAP.
1.2).
(PL
9.2).
A
P/J417B-5, Logic (L)
P/J417B-4, +2.5 VDC
P/J417B-3, Logic (L)
P/J417B-2, Logic (L)
Go to
Flag 4
on BSD 4.1 and check for an open /short circuit.
Replace the Main Motor
(PL
Replace the IOT Drive PWB
Perform the following:
While in [04-007] Component Control and the Main Motor is running, check for the follow-
ing conditions at
P/J417B-5, Logic (L)
P/J417B-4, +2.5 VDC
P/J417B-3, Logic (L)
P/J417B-2, Logic (L)
Go to
Flag 4
on BSD 4.1 and check for an open /short circuit.
Replace the Main Motor
(PL
1.2).
Replace the IOT Drive PWB
(PL
1/05
2-37
1.2).
(PL
9.2).
9.2).
Status Indicator RAPs