OF4-001 Main Motor RAP
This RAP is used to repair the Main Motor and Drum Motor circuit failures when directed by
another RAP.
Initial Actions
•
Refer to BSD 4.1, Main and Drum Drive Control, in the following procedure:
•
Check the Drive Mechanism for damage, jams, and obstructions.
Procedure
Go to
Flag 1
BSD 4.1 and check for +5 VDC at P/J42-14 on the Distribution PWB. +5 VDC is
measured at P/J42-14 on the Distribution PWB.
Y
N
Perform the following:
•
Go to
Flag 1
BSD 4.1 and check for a short/open circuit.
•
Go to the
+5 VDC Power (IOT LVPS)
Perform the following:
•
Enter DC330 004-007 Main Motor, Press Start and Stop.
•
Check for a change of state from (L) to +5 VDC at P/J417B-5 on the IOT Drive PWB.
The voltage at P/J417B-5 switched between (L) and +5 VDC at P/J417B-5 on the IOT
Drive PWB.
Y
N
Perform the following:
•
Go to
Flag 3
on BSD 4.1 and check for an open/short circuit.
•
Replace the Main Motor
(PL
1.2).
•
Replace the IOT Drive PWB
(PL
Go to
Flag 2
on BSD 4.1 and check for +24 VDC at P/J42-11 and 12, on the Distribution PWB.
+24 VDC is measured at
P/J42
-11 and 12, on the Distribution PWB.
Y
N
Perform the following:
•
Go to
Flag 2
on BSD 4.1 check for an open/short circuit.
•
Go to the
+24 VDC Power (IOT LVPS)
Enter DC330 004-007 Main Motor. Press Start. The Main Motor runs.
Y
N
Check for Logic (L) at P/J417B-5. Logic (L) is measured at P/J417B-5.
Y
N
Perform the following:
•
Go to on
Flag 4
BSD 4.1 and check for an open/short circuit.
•
Replace the Main Motor
(PL
•
Replace the IOT Drive PWB
Perform the following:
•
While exercising [04-021] in Component Control, check for a change of state on the
Main Motor On line P/J417B-5.
•
While in [04-021] Component Control and the Main Motor is running, check for the
following conditions at
A
Reissue
DocuColor 12/DCCS50
RAP.
9.2).
RAP.
1.2).
(PL
9.2).
A
–
P/J417B-5, Logic (L)
–
P/J417B-4, +2.5 VDC
–
P/J417B-3, Logic (L)
–
P/J417B-2, Logic (L)
•
Go to
Flag 4
on BSD 4.1 and check for an open /short circuit.
•
Replace the Main Motor
(PL
•
Replace the IOT Drive PWB
Perform the following:
•
While in [04-007] Component Control and the Main Motor is running, check for the follow-
ing conditions at
–
P/J417B-5, Logic (L)
–
P/J417B-4, +2.5 VDC
–
P/J417B-3, Logic (L)
–
P/J417B-2, Logic (L)
•
Go to
Flag 4
on BSD 4.1 and check for an open /short circuit.
•
Replace the Main Motor
(PL
1.2).
•
Replace the IOT Drive PWB
(PL
1/05
2-37
1.2).
(PL
9.2).
9.2).
Status Indicator RAPs