dC131 Fuser NVM List (777)

Table 1 Fuser NVM list (777)
Chain-
Link
Name
Default
777-001 TEMP1
160
777-002 TEMP2
130
777-003 TEMP3
178
777-006 TEMP8
143
777-007 TEMP9
130
777-008 TEMP10
165
777-010 TEMP12
158
777-011 TEMP13
115
777-012 TEMP14
165
777-051 OIL PUMP ON
3000
777-055 OIL CV CNTR
0
777-056 OIL NEAR TO EMP
2000
777-058 OIL LIMIT TIME
10
777-075 WEB NEMP
1994
777-077 WEB STATE
0
777-079 WEB MOT ON TIME (L) 0
777-081 AIR TMP
0
777-082 ENV TIME
30
777-083 ENV TARGET
20
General Procedures
dC131 Fuser NVM List (777)
Range
Description
150-165 H/R1st temperature control
(Unit:degree (C))
70-135
P/R1st temperature control
(Unit:degree (C))
170-198 Ext H/R1st temperature control
(Unit: degree (C))
100-160 H/R Power save temperature
(Unit: degree (C))
70-135
P/R Power save temperature
(Unit: degree (C))
100-180 Ex. H/R Power save temperature
(Unit: degree (C))
150-160 H/R Ready temperature (Unit:
degree (C))
70-130
P/R Ready temperature (Unit:
degree (C))
165-180 Ex. H/R Ready temperature (Unit:
degree (C))
40-
OIL PUMP ON time (ms)
10000
Number of pages ejected after
OIL NEAR EMPTY (Max: 5000)
500-
Number of pages allowed from
3000
NEAR EMPTY to EMPTY.
1-20
Time allowed after OIL NEAR
EMPTY/EMPTY (Unit: Minute)
0-65534 Accumulated ON time threshold
to detect WEB NEAR EMPTY
(Minute)
-
Displays the WEB status.
0=Full
1=Near Empty
2=Empty
0-65535 Indicates Web material used.
7000 = 1 inch of Web.
-
Environment temperature
-
Environment temperature moni-
toring interval (min)
-
Environment temperature correc-
tion threshold
Chain-
Link
Name
777-109 SIZE MIX TIME
777-110 SIZE MIX DEF
777-135 TH0 4C NOR
777-136 TH0 BW NOR
777-137 TH0 4C HVY
777-138 TH0 BW HVY
777-139 TH0 4C OHP
777-140 TH0 BW OHP
777-160 LAMP OVHT FAIL
777-231 HR TEMP
777-232 PR TEMP
777-233 Ext HR TEMP
777-321 Auto Set Up NVM
1/05
6-92
manuals4you.com
manuals4you.com
Table 1 Fuser NVM list (777)
Default
Range
Description
5
1-15
Threshold to determine whether
to do a dry run for size mix paper
feed interval. (Unit= Minute)
0
0-1
Determines whether to do a dry
run for size mix paper feed inter-
val.
0= Yes 1= No
193
100-200 HR & PR Not Ready temperature
start threshold: 4C/Normal paper
170
100-200 BW, Normal paper
190
100-200 4C, Thick paper
183
100-200 BW, Thick paper
195
100-200 4C, OHP
213
100-200 BW, OHP
0
0-7
Overheating fault
0= None
1=HR
2=HR Safety
3=PR
4=PR Safety
5=Ext HR
6=Ext HR Safety
7= Environment sensor
0
-
HR temperature: Current calcu-
lated value
0
-
PR temperature: Current calcu-
lated value
0
-
Ext HR temperature: Current cal-
culated value
0
0-1
Automatic Set Up
0= Yes (default)
1= No