9-344/9-434 Ibt Cleaner Contact Fail Rap - Xerox DocuColor 12/DCCS50 Service Manual

Table of Contents

Advertisement

9-344/9-434 IBT Cleaner Contact Fail RAP

The Control Logic has detected that the IBT Cleaner failed to contact the IBT.
Initial Actions
Refer to BSD 9.11 and BSD 9.15 for the following procedure.
Ensure that
P/J417A
and
P/J418B
Retract Clutch, and
P/J111
on the IBT Clean Blade Home Position Sensor are connected
before beginning this RAP.
Procedure
Stack the codes dC330 004-007 Main Motor and 009-066 IBT Cleaner Contact.
Enter dC330 009-216 IBT Cleaner Retract Home Sensor. Press Start. The Display is (H)
Y
N
Remove the IBT
REP 7.1.1
(Reinstall IBT after test is completed). Manually block the IBT
Clean Home Position Sensor. The display changes to (H)
Y
N
+5 VDC is measured between P/J418B-5 and GND on the IOT Drive PWB.
Y
N
+5 VDC is measured between P/J418B-6 and P/J418B-4 on the IOT Drive
PWB.
Y
N
Go to the +5 VDC (IOT) Wirenet and check the wires between
on the IOT LVPS and P/J418B8-6 on the IOT Drive PWB. Go to the DC
COM (IOT) Wirenet and check the wires between P/J21-5 on the IOT
LVPS and P/J418B-4 on the IOT Drive PWB.
Go to
Flag 1
on BSD 9.11 and check the wire for a short circuit to ground. Go to
Flag 3
on BSD 9.11. Check the wires for an open circuit. If the wires are good,
replace the IBT Clean Blade Home Position Sensor
Replace the IOT Drive PWB (PL 9.2).
Enter dC330 009-059 2ND Belt Transfer Roll Retract. Press Start. Enter dC330 009-067
IBT Cleaner Retract. Press Start. The Cleaner Retract Clutch energizes.
Y
N
+24 VDC is measured between P/J417A-9 and P/J417A-10 on the IOT Drive
PWB.
Y
N
+24 VDC is measured between P/J417A-9 and GND on the IOT Drive
PWB.
Y
N
Go to the +24 VDC-4 Wirenet and check the wires between P/J24-2 on
the IOT LVPS and P/J417A-9 on the IOT Drive PWB.
Go to
Flag 2
on BSD 9.11. Check the wires for an open circuit or a short circuit.
If the wires are good, replace the IOT Drive PWB
tinues, replace the Cleaner Retract Clutch
A
B
C
Reissue
DocuColor 12/DCCS50
on the IOT Drive PWB,
P/J252
on the Cleaner
(PL
7.3).
(PL
9.2). If the problem con-
(PL
1.3).
A
B
C
Go to
Flag 2
on BSD 9.11 and check the wires for an open circuit. If the wires are
good, replace the Cleaner Retract Clutch
Check the Cleaner Retract Clutch for binding or intermittent operation. If the Cleaner
Retract Clutch is good, replace the IBT Clean Blade Home Position Sensor
problem continues, replace the Cleaner Retract Clutch
Replace the IOT Drive PWB
P/J21
-1
1/05
9-344/9-434 IBT Cleaner Contact Fail RAP
2-111
(PL
1.3).
(PL
1.3).
(PL
9.2).
(PL
7.3). If the
Status Indicator RAPs

Advertisement

Table of Contents
loading