REP 3.1.1 Platen Glass

Parts List on
PL 3.1
Removal
Ensure that Tag 8, IIT Support Weld Brace Kit, is installed before the following removal proce-
dure is performed.
Turn power off and disconnect the power plug.
1.
Open the Platen Cover.
2.
Remove the Platen Glass
(Figure
1).
1. Remove the screws (2).
2. Remove the Right Side Plate.
3. Remove the Platen Glass.
Figure 1 Remove the Platen Glass
Reissue
DocuColor 12/DCCS50
CAUTION
WARNING
Installation
NOTE: Press the Platen Glass in the direction of arrow A; Press the Right Side Plate in the
direction of arrow B
(Figure
2).
1/05
4-51
Figure 2 Reassembly