Dc131 Procon1 Nvm List (773) - Xerox DocuColor 12/DCCS50 Service Manual

Table of Contents

Advertisement

Table 1 Billing NVM List (900)
Chain-
Link
Name
990-019 B/W Print billing meter (Upper)
(Half-Tone EEP-ROM)
990-020 B/W Print billing meter (Lower)
(Half-Tone EEP-ROM)
990-021 Large Size Full Color billing meter
(Upper) (Half-Tone EEP-ROM)
990-022 Large Size Full Color billing meter
(Lower) (Half-Tone EEP-ROM)
990-023 Large Size B/W billing meter
(Upper) (Half-Tone EEP-ROM)
990-024 Large Size B/W billing meter
(Lower) (Half-Tone EEP-ROM)
990-025 Full Color Copy billing meter
(Upper) (NVM)
General Procedures
dC131 BILLING NVM List (990), dC131 Procon1 NVM
Default Range
Description
-
-
B/W Print electronic billing
(019& 020: One billing)
-
-
(019& 020: One)
-
-
Large Size Full Color elec-
tronic billing (021& 022: One
billing)
-
-
(021& 022: One)
-
-
Large Size B/W electronic
billing (023& 024: One bill-
ing)
-
-
(023& 024: One)
-
-
Full Color Copy electronic
billing (025& 026: One bill-
ing)

dC131 Procon1 NVM List (773)

Chain-
Link
Name
773-001 DISP SW
773-002 ELEC SW
773-007 TRC SW
773-011 Vclean Fail
773-012 VHVM Fail
773-013 LDCONT Fail
773-014 Hum Fail
1/05
6-84
manuals4you.com
manuals4you.com
Table 1 Procon 1 NVM List (773)
Default
Range
Description
1
0-65535 Toner control switch
0= Display control by NVM
timer
1= Display control by
ADC+ICDC
2 or more= Display control by
ICDC
1
0-65535 Potential/Light control switch
0= Fixed NVM (773-401 - 773-
404): VG control, Fixed NVM
(773-421): LD control, Fix
NVM: BIAS/ASG control (VH/
VM Setup and LDCONT func-
tions: Not done) (VH/VM patch:
Created and measured,
LDCONT VM patch: Not cre-
ated)
1= VH/VM Setup - VG/BIAS/
ASG value corrected, LD
CONT-LD value corrected
2 or more= VH/VM Setup - VG/
BIAS value/LD value corrected
(LDCONT function not done.
No VM patch is created)
1
0-65535 Gray scale control switch
0= LUT through - ADC patch is
measured.
1= LUT calculation in the Gray
scale control (TRC CONT MIN/
JOB)
2= LUT calculation only in TRC
CONT MIN. ADC measure-
ment.
3 or more= LUT is not calcu-
lated. ADC patch is measured.
0
0-65535 Vclean measurement= Number of
Faults (Hidden Fault)
0
0-65535 VH/VM Setup= Number of Faults
(Hidden Fault)
0
0-65535 LD CONTROL= Number of Faults
(Hidden Fault)
0
0-65535 Humidity measurement= Number of
Faults (Hidden Fault)
Reissue
DocuColor 12/DCCS50

Advertisement

Table of Contents
loading

Table of Contents