Xerox DocuColor 12/DCCS50 Service Manual page 759

Table of Contents

Advertisement

Table 1 PH NVM List (761)
Chain-
Link
Name
Default
761-354 ARRIVE AT TRAY4
0
PRE FEED SEN-
SOR INDICATE
POINT
761-355 ARRIVE AT TRAY 1
0
FEED OUT SEN-
SOR INDICATE
POINT
761-356 ARRIVE AT TRAY 2
0
FEED OUT SEN-
SOR INDICATE
POINT
761-357 ARRIVE AT TRAY 3
0
FEED OUT SEN-
SOR INDICATE
POINT
761-358 ARRIVE AT TRAY 4
0
FEED OUT SEN-
SOR INDICATE
POINT
761-359 ARRIVE AT PRE
0
REGI SENSOR
INDICATE
POINT(USED
TRAY 1)
Reissue
DocuColor 12/DCCS50
Range
Description
0-9
Shows the location of the latest timings
(761-131-140) (#4 Pre-Feed Sensor
arrival timings 1-10)
e.g.; If the value is 5, the latest data is
saved in 5, the previous data is saved in
4, and the data prior to the previous data
is saved in 3.
0-9
Shows the location of the latest timings
(761-141-150) (#1 Feed Out Sensor
arrival timings 1-10)
e.g.; If the value is 5, the latest data is
saved in 5, the previous data is saved in
4, and the data prior to the previous data
is saved in 3.
0-9
Shows the location of the latest timings
(761-151-160) (#2 Feed Out Sensor
arrival timings 1-10)
e.g.; If the value is 5, the latest data is
saved in 5, the previous data is saved in
4, and the data prior to the previous data
is saved in 3.
0-9
Shows the location of the latest timings
(761-161-170) (#3 Feed Out Sensor
arrival timings 1-10)
e.g.; If the value is 5, the latest data is
saved in 5, the previous data is saved in
4, and the data prior to the previous data
is saved in 3.
0-9
Shows the location of the latest timings
(761-171-180) (#4 Feed Out Sensor
arrival timings 1-10)
e.g.; If the value is 5, the latest data is
saved in 5, the previous data is saved in
4, and the data prior to the previous data
is saved in 3.
0-9
Shows the location of the latest timings
(761-181-190) (#1 Pre-Regi Sensor
arrival timings 1-10)
e.g.; If the value is 5, the latest data is
saved in 5, the previous data is saved in
4, and the data prior to the previous data
is saved in 3.
Table 1 PH NVM List (761)
Chain-
Link
Name
Default
761-360 ARRIVE AT PRE
0
REGI SENSOR
INDICATE
POINT(USED
TRAY 2)
761-361 ARRIVE AT PRE
0
REGI SENSOR
INDICATE
POINT(USED
TRAY 3)
761-362 ARRIVE AT PRE
0
REGI SENSOR
INDICATE
POINT(USED
TRAY 4)
761-363 ARRIVE AT REGI
0
SENSOR INDI-
CATE
POINT(USED
TRAY 1)
761-364 ARRIVE AT REGI
0
SENSOR INDI-
CATE
POINT(USED
TRAY 2)
761-365 ARRIVE AT REGI
0
SENSOR INDI-
CATE
POINT(USED
TRAY 3)
1/05
6-79
Range
Description
0-9
Shows the location of the latest timings
(761-191-200) (#2 Pre-Regi Sensor
arrival timings 1-10)
e.g.; If the value is 5, the latest data is
saved in 5, the previous data is saved in
4, and the data prior to the previous data
is saved in 3.
0-9
Shows the location of the latest timings
(761-201-210) (#3 Pre-Regi Sensor
arrival timings 1-10)
e.g.; If the value is 5, the latest data is
saved in 5, the previous data is saved in
4, and the data prior to the previous data
is saved in 3.
0-9
Shows the location of the latest timings
(761-211-220) (#4 Pre-Regi Sensor
arrival timings 1-10)
e.g.; If the value is 5, the latest data is
saved in 5, the previous data is saved in
4, and the data prior to the previous data
is saved in 3.
0-9
Shows the location of the latest timings
(761-221-230) (#1 Regi Sensor arrival
timings 1-10)
e.g.; If the value is 5, the latest data is
saved in 5, the previous data is saved in
4, and the data prior to the previous data
is saved in 3.
0-9
Shows the location of the latest timings
(761-231-240) (#2 Regi Sensor arrival
timings 1-10)
e.g.; If the value is 5, the latest data is
saved in 5, the previous data is saved in
4, and the data prior to the previous data
is saved in 3.
0-9
Shows the location of the latest timings
(761-241-250) (#3 Regi Sensor arrival
timings 1-10)
e.g.; If the value is 5, the latest data is
saved in 5, the previous data is saved in
4, and the data prior to the previous data
is saved in 3.
General Procedures
dC131PH NVM List (761)

Advertisement

Table of Contents
loading

Table of Contents