9-634 ADC Out Of Range RAP
The selected gain for ADC was out of range.
Initial Actions
•
Refer to BSD 9.8 and BSD 9.15 for the following procedure.
•
Clean the ADC Sensor.
•
Clean the IBT Belt.
•
Check that the
P/J139
on the ADC Sensor PWB, IBT connector J702A,
J416A
on the IOT Drive PWB are firmly connected.
Procedure
Go to
Flag 7
and
Flag 8
on BSD 9.8. Check the wires for an open circuit or a short circuit. If the
wires are good, replace the ADC Sensor
Drive PWB
(PL
9.2).
Reissue
DocuColor 12/DCCS50
J702B
(PL
7.5). If the problem continues, replace the IOT
9-662 LD Out Of Range RAP
The selected LD value was out of range.
Initial Actions
•
Refer to BSD 9.1and BSD 9.15 for the following procedure.
•
Clean the ESV Sensor.
•
Check that
P/J141
on the ESV Sensor, and
connected.
and
P/
Procedure
Perform the following in the order listed.
•
Go to the
IQ 38 Charge Corotron HVPS RAP
proper operation.
•
Ensure that the Charge Corotron Wire and Grid are in good condition.
•
Go to
Flag 6
and
Flag 7
If the wires are good, replace the ESV Sensor
the IOT Drive PWB
(PL
•
Replace the Xerographic CRU (Drum) (Section 6,
1/05
9-634 ADC Out Of Range RAP, 9-662 LD Out Of
2-133
P/J422A
on the IOT Drive PWB are firmly
and check the Charge Corotron HVPS for
on BSD 9.1. Check the wires for an open circuit or a short circuit.
(PL
5.1). If the problem continues, replace
9.2).
Machine
Consumables).
Status Indicator RAPs