Table 1 dC Routines
dC Number
Name
132
Set Machine Serial Number.
Read Billing Meter Information
135
Service Data
HFSI Counter
140
Component Check: Analog Monitor
188
Service Mode Exit Screen
301
NVM access: NVM initialization
305
System Test: Component Operation
Check UI Component Check
330
Component Check: Component Con-
trol
Reissue
DocuColor 12/DCCS50
Description
If you have replaced the PWB that
has a Machine Serial Number, check
the PWB and set the Machine Serial
Number.
Reads Billing Meter Information for
the following:
IOT CPU PWB
Half-Tone PWB
IOT NVM PWB
Displays the regular part replacement
life expectancy (threshold) and cur-
rent value (usage). You can change
the replacement life expectancy to a
preset value in the PWS database
and reset the current value.
Monitor the analog values of the sen-
sors (A/D conversion) while operating
the components (e.g., C.C). You can
temporarily change the output value.
Displays the requirements for exit
from the Service Mode.
Commands NVM Data initialization
for initialization of:
IISS
Post IPS
IOT
SYS
UI
Checks the UI Screen and Compo-
nent Panel Button operation.
Displays the instructions and results
of the Input Component Check and
Output Component Check
1.
You can monitor each Input
Component or check the opera-
tion of each Output Component.
2.
You can simultaneously check
multiple Input Components and
Output Components up to 11
total.
1/05
6-21
Table 1 dC Routines
dC Number
Name
351
NVM Background Processing
361
NVM access: Save/Restore NVM
371
Configuration Page
391
Edit Pad
612
Color Test Pattern Print
701
Other Adjust/Set: Fuser Nip Measure-
ment
740
Tray 5 (Bypass) guide adjustment
915
Machine data output: XERO data dis-
play
918
IOT Highlight Setup
919
Color Balance Setup
(IIT machine only)
Description
1.
Saves and restores values of all
NVM in PWS dC131 databank.
NOTE: Background Read must
complete prior to saving.
2.
Start and Stop background NVM
Read.
3.
Saves/restores machine set-
tings. Saves NVM values listed:
4.
Resets all HFSI.
Saves the machine NVM data in the
PWS. Restores the machine NVM
data (stored in the PWS) back to the
machine.
Allows viewing of current software
version and Market Place setting,
Machine Configuration, Output
Device(s), Accessories, Tray 1 Paper
Size setting, Feature Config., and
Input Device.
These settings can be changed to
align with the machine configuration.
Can change the Edit Pad custom
color(s).
1.
Outputs a test pattern to identify
a copy quality problem.
2.
Generates a test pattern from
the Pattern Generator in the
machine.
Make a copy for a contact arc adjust-
ment and measure the fuser nip width
by a simple operation.
1.
Re-calibrate Size Sensor
2.
Check if the Tray 5 guide size in
the width direction has been
properly detected.
Displays the machine Xerographic
data in the PWS in a format that is
easy to see and understand.
Uniform the Highlight Density Repro-
duction Starting Point (for each K, Y,
M, C) and the Highlight Density of In/
Out.
Make a 4C copy in the Photo mode.
Adjust the YMCK color balance.
General Procedures