3-340 IOT RAM Fail RAP

This Fault Code indicates that it was detected at power on that the IOT PWB RAM Test failed.
Initial Actions
Refer to BSD 3.12 Monitoring in this procedure:
Check the NVM settings related to the IOT-SYS logic.
Procedure
PO/PO the machine. Fault Code 3-340 is still declared.
Y
N
If intermittent behavior is suspected, perform the following:
Inspect the IOT NVM PWB and the IOT CPU PWB connections.
Reseat connectors between the IOT NVM PWB and IOT CPU PWB
Replace the IOT NVM PWB
(PL
9.2).
Status Indicator RAPs
3-340 IOT RAM Fail RAP, 3-356 IOT NVM Failure RAP

3-356 IOT NVM Failure RAP

This Fault Code indicates that the IOT PWB NVM test failed and was detected at Power On.
Initial Actions
Refer to BSD 3.12 Monitoring in this procedure:
Procedure
PO/PO the machine. Fault Code 3-356 is still declared.
Y
N
If intermittent performance is suspected, inspect the IOT CPU PWB, and the IOT NVM
PWB for loose connections or any obvious electrical/mechanical cause for malfunction.
Replace the IOT NVM PWB