Rep 8.7.2 Oil Wick - Xerox DocuColor 12/DCCS50 Service Manual

Table of Contents

Advertisement

REP 8.7.2 Oil Wick

Parts List on
PL 8.7
Removal
Turn power off and disconnect the power plug.
Since the Fuser is very hot, wait until the Fuser becomes sufficiently cold.
NOTE: After replacing the Oil Wick, reset the HFSI counter. Enter the
List
Diag. Screen (010-814).
1.
Open the Front Door.
2.
Remove the Fuser Unit
(REP
8.1.1).
3.
Remove the following parts:
a.
Front Cover
(PL
8.1)
b.
Top Cover
(PL
8.2)
4.
Remove the Oil Pipe
(Figure
1).
1. Loosen the clamp.
2. Remove the Oil Pipe.
Figure 1 Remove the Oil Pipe
Repairs and Adjustments
REP 8.7.2
WARNING
CAUTION
dC135 HFSI Counter
5.
Remove the Oil Wick
(Figure
1. Remove the screws (3).
2. Remove the Oil Wick and, if present, the backup plate.
Installation
1.
Reinstall the parts in the reverse order of disassembly.
2.
Perform the Standard Fuser Break-In Procedure
1/05
4-132
manuals4you.com
manuals4you.com
2).
Figure 2 Remove the Oil Wick
(GP 1 Fuser Break-In
DocuColor 12/DCCS50
Procedure).