REP 8.1.1 Fuser Unit

Parts List on
PL 8.1
Removal
NOTE: After replacing the Fuser Unit, clear all HFSI counters related to the Fuser.
Turn power off and disconnect the power plug.
Since the Fuser is very hot, wait until the Fuser becomes sufficiently cold.
1.
Open the Front Door.
2.
Push the lever down and pull out the Drawer Assembly.
3.
Pull the Drawer Assembly out to a maintenance position
1. Push in the stoppers at both sides.
2. Pull out the Drawer Assembly.
Figure 1 Pull out the Drawer Assembly
NOTE: Spread a drop cloth on the floor before removing the Oil Cartridge, in order to
avoid any spills.
4.
Remove the following parts:
Reissue
DocuColor 12/DCCS50
WARNING
CAUTION
(Figure
1).
1. Lever
(PL
2.22)
2. Drawer Cover
(PL
2.18)
3. Oil Cartridge
(PL
8.1)
5.
Remove the Fuser Unit
(Figure
1. Lower the baffle.
2. Loosen the screws (2).
3. Remove the bracket.
4. Disconnect the connector.
5. Remove the Fuser Unit.
Figure 2 Remove the Fuser Unit
Installation
NOTE: Make sure to re-connect the connector when the Fuser Unit is installed.
1.
Reinstall the parts in the reverse order of disassembly.
2.
Perform the Full Fuser Break-In Procedure
3.
Perform the Fuser Nip adjustment
1/05
4-115
2).
(GP 1 Fuser Break-In
Procedure).
(ADJ
8.1.1).
Repairs and Adjustments
REP 8.1.1