9-614 VClean Out Of Range RAP
The measured untoned ADC patch was out of range.
Initial Actions
•
Refer to BSD 9.8 and BSD 9.15 for the following procedure.
•
Clean the ADC Sensor.
•
Clean the IBT Belt.
•
Check that the
P/J139
on the ADC Sensor PWB, IBT connector J702A,
J416A
on the IOT Drive PWB are firmly connected.
Procedure
Perform the following in the order listed.
•
Go to the
IQ 38 Charge Corotron HVPS RAP
proper operation.
•
Ensure that the Charge Corotron Wire and Grid are in good condition.
•
Go to
Flag 7
and
Flag 8
on BSD 9.8. Check the wires for an open circuit or a short circuit.
If the wires are good, replace the ADC Sensor
the IOT Drive PWB
(PL
9.2).
•
Replace the Xerographic CRU (Drum) (Section 6,
Status Indicator RAPs
9-614 VClean Out Of Range RAP, 9-619 VClean TRC
J702B
and
and check the Charge Corotron HVPS for
(PL
7.5). If the problem continues, replace
Machine
Consumables).
manuals4you.com
manuals4you.com
9-619 VClean TRC Out Of Range RAP
The measured untoned TRC patch density was out of range.
Initial Actions
•
Refer to BSD 9.8 and BSD 9.15 for the following procedure.
•
Clean the ADC Sensor.
•
Clean the IBT Belt.
P/
•
Check that the
P/J139
on the ADC Sensor PWB, IBT connector J702A,
J416A
on the IOT Drive PWB are firmly connected.
Procedure
Perform the following in the order listed.
•
Go to the
IQ 38 Charge Corotron HVPS RAP
proper operation.
•
Ensure that the Charge Corotron Wire and Grid are in good condition.
•
Go to
Flag 7
and
Flag 8
on BSD 9.8. Check the wires for an open circuit or a short circuit.
If the wires are good, replace the ADC Sensor
the IOT Drive PWB
(PL
9.2).
•
Replace the Xerographic CRU (Drum) (Section 6,
1/05
2-132
J702B
and
and check the Charge Corotron HVPS for
(PL
7.5). If the problem continues, replace
Machine
Consumables).
Reissue
DocuColor 12/DCCS50
P/