dC129 System Registration Adjustment

Purpose
Performs the Lead Registration and Side Registration Adjustments by looking at the output of
the built-in Test Pattern for adjustment.
NOTE: For details on the dC129 System Registration adjustment, see
Lead Edge Registration (dC129: System Registration Adjustment).
Procedure
1.
Enter the Service Diagnostics Mode. Refer to
using the
PWS.
2.
Select the Adjustments Tab on the Service Entry Screen.
3.
Select Other Adjustments Tab on the Adjustment/Setup Screen. The System Registra-
tion Adjustment Screen is displayed.
4.
Specify the Tray at the Tray/Size pull-down and the number of copies at the Print Count
Window.
NOTE: Tray1 is the default Tray and cannot be changed to another Tray from the PWS.
NOTE: Number of copies can be set between 1-99.
NOTE: Selecting Print All will print a test pattern from each tray.
5.
Select Print All. The message, executing System Registration Setup (dc129) is dis-
played.
6.
The specified number of built-in patterns is output and the message, "Completed" is dis-
played in the status area.
a.
The message screen informing that the Main Processor is, "abnormal" will be dis-
played if Test Copy of the built-in pattern cannot be executed.
7.
Add/Subtract the Registration Adjustment Value by looking at the copy. Using the arrows
for the "Lead Reg" and "Side Reg", adjust the Lead and Side Registrations:
a.
Lead Reg. 1step (click) =.1100mm. Maximum steps (clicks) = 100
b.
Side Reg. 1step (click) = 0.0423mm. Maximum steps (clicks) = 300
8.
Select Set Adjust Value after confirming the Registration Adjustment Value.
a.
"Current NVM Value" of the Lead Registration/Side Registration are renewed when
this, "Set Adjust Value" and "Save (LR)" is selected. Restore (LR) and Restore (SR)
buttons will restore the "Current NVM Value" to the initial value.
b.
"NVM Value at Save" is displayed. This display will be changed when Save (LR) or
Save (SR) is selected again.
c.
Save (LR), Save (SR) will save "LR" or "SR" NVM in "NVM Value at Save".
9.
The message, "In Progress" is displayed.
a.
When the machine cannot change the NVM value, the message, "! Unable to set up
adjustment value. Cancel Adjustment Value Setup" is displayed on the Information
screen.
10. Verify the adjustment by printing another pattern.
11. If the pattern does not meet Image Quality requirements, repeat steps 8-11 of this adjust-
ment procedure.
General Procedures
dC129 System Registration Adjustment, dC131 NVM
ADJ
9.1.10: IOT Side/
Entering the Service Diagnostic Mode
1/05
6-26
manuals4you.com
manuals4you.com

dC131 NVM Read/Write

Purpose
Reads, sets or changes the NVM data.
NOTE: You can access all NVMs including the NVM for a key operator. The billing forgery pre-
vention function and the auditron administration password cannot be overwritten.
Procedure
Module Selection
1.
Enter the Service Diagnostics Mode. Refer to
using the
PWS.
2.
Select Adjustments in the Service Entry Screen.
3.
The system displays one of the Read/Write Screens. dC131 NVM Read/Write is the
default screen.
4.
Select a Sub-System from the Vertical Left Tab List. The default tab is 'All'.
Table 1 Module Selection
Module item
All
UI/Tools
IISS
Config
ROS
IPS
PHM
System
Xero
Drives / Output
ProCon
Developer
Fuser
Other
Errors (number of errors)
Changed (number pending change)
Reading NVM
1.
Select an ID from the Sub-System Table, then click Read NVM or double click on the line
ID (line) and the value will be read in the value column. The "Range Check" column will fill
in.
Entering the Service Diagnostic Mode
Chain number allocation
700 - 999
700,702
715
719
720
730
740, 749, 760, 761
752, 759
771, 774
772, 780, 790
773
776
777
775, 800, 850
Displays and NVM outside of the ranges listed
in the PWS database.
Displays any with new value entered in the
"New" column, but not written yet.