15-371 X - Fail 6RAP
The control logic on the Pre IPS PWB detected a hardware failure.
Initial Actions
•
Refer to BSD 6.7 in the following procedure:
•
Ensure that
P/J560
on the Pre IPS PWB and the BR PWB is fully seated.
Procedure
PO/PO the machine. If the fault continues, replace the following:
•
Pre IPS PWB
(PL
3.5)
•
BR PWB
(PL
3.5)
Status Indicator RAPs
15-371 X - Fail 6RAP, 15-380/15-381 / 15-382 / 15-383 /
15-380/15-381 / 15-382 / 15-383 / 15-384 / 15-385 CCD AGC
Fail RAP
The Automatic Gain Control (AGC) for a specific channel from the CCD PWB failed.
15-380: CCD Channel 1 RED (odd) AGC Fail
15-381: CCD Channel 2 RED (even) AGC Fail.
15-382: CCD Channel 3 GREEN (odd) AGC Fail.
15-383: CCD Channel 4 GREEN (even) AGC Fail.
15-384: CCD Channel 5 BLUE (odd) AGC Fail.
15-385: CCD Channel 6 BLUE (even) AGC Fail.
Initial Actions
•
Refer to BSD 6.1, BSD 6.2, and BSD 6.7 in the following procedure.
•
Verify that the Platen Glass is installed correctly.
•
Verify that the following NVM values match the Machine Configuration on the Platen or
the DADF: NVM715-125: 0=Platen, 1=DADF.
Procedure
Enter dC330 006-002 ITT Exposure Lamp. Press Start. The Exposure Lamp lights.
Y
N
Go to the
6-371 Exposure Lamp Fail
The Exposure Lamp lights at the correct intensity without flickering.
Y
N
Go to
Flag 1
on BSD 6.1 and check the wires for an open or short circuit. Verify that
J535
on the Lamp Ballast PWB and
are connectors are OK, replace the following:
•
Exposure Lamp
(PL
•
Lamp Ballast PWB
•
IIT Driver PWB
(PL
The White Reference Strip on the bottom of the Platen Glass (Platen top machines
3.1) or underneath the Plate
Y
N
Clean the White reference Strip or replace the Platen Glass
12.11) on DADF equipped machines.
Go to
Flag 1
on BSD 6.2 and check the Flat Cable
the CCD PWB for damage. Reseat the Flat Cable. If the problem continues, replace the follow-
ing:
•
CCD PWB
(PL
3.2)
•
Pre-IPS PWB
(PL
3.5)
1/05
2-224