009-038 (ATC_LED): actuates the LED ON/OFF.
009-039 (Opening/closing of the shutter and TC measurement):
Measurement of the TC: NVM 775-982 (This function requires that the desired developer
housing is facing the ATC Sensor. Perform the following steps:
a.
Enter sub-system check on the UI and sub-system test on the PWS for machine
diagnostics. Select developer unit check.
b.
For best observation, remove machine Right Upper Cover PL 11.2.
c.
Press Start (if using the UI) or move desired developer into position. Please note the
ATC Sensor is opposite the development position. (UI diagnostics) Select Black,
results in Yellow at ATC Sensor position. Select Magenta, results in Cyan at ATC
Sensor position. Select Cyan results in Black at ATC Sensor position. Select Yellow,
results in Home position. Select Home, results in Magenta at ATC Sensor position.
d.
Close "developer unit check" screen. The desired developer housing remains in
position.
e.
Enter dC330 Component control. Enter 009-039 and press Start. (Shutter activa-
tion). Close dC330.
f.
Enter NVM read \ write. NVM 775-982 = TC reading for desired color. (Black is not
detectable with ATC Sensors) Value range 140 ~ 200 for selected color.
g.
If 775-982 is out of given range, perform steps b) through h) of Appendix 1. If prob-
lem continues refer to "Hardware Repairs".
9.
Check the following NVM and ensure the values are set to given value. Correct values if
needed and repeat steps b) through g) of Appendix 1
NVM designation
TH2_100_PV_K
K_Delta_VHS_HUM_DWN
K_Delta_VMS_HUM_DWN
K_Delta_BIAS_HUM_DWN
K_Delta_Radc_SET_HUM_K_DWN
TH1_G100(K)
TH2_G100(K)
Delta_RADCS_100_MAX_K
ATC_CTRL_SW
TC_OFFSET_OUT_TH
TC_Ref_OUT_MIN
TC_Ref_OUT_MAX
TC_OUT_Adj_MAX
TC_Ref
TC_SET[Y]
TC_SET[M]
TC_SET[C]
TC_OUT_Hilimit1[Y]
TC_OUT_Hilimit1[M]
TC_OUT_Hilimit1[C]
Image Quality
IQ 47 ATC Sensor RAP
Table 3
Chain
Link
SET value
773
223
200
773
286
961
773
287
250
773
289
624
773
309
0
775
664
65
775
669
60
775
673
100
775
731
1
775
773
200
775
776
200
775
777
600
775
779
350
775
783
420
775
784
173
775
785
173
775
786
175
775
821
30
775
822
30
775
823
30
NVM designation
TC_OUT_Hilimit2[Y]
TC_OUT_Hilimit2[M]
TC_OUT_Hilimit2[C]
TC_OUT_Lolimit1[Y]
TC_OUT_Lolimit1[M]
TC_OUT_Lolimit1[C]
TC_CNT_Hi2_MAX
TC_CNT_Lo2_MAX
TC_CYAN_OFFSET
TC_RADCS_UP_STEP2
TC_RADCS_DWN_STEP2
Delta_RADCS_TC_MAX[Y]
Delta_RADCS_TC_MAX[M]
Delta_RADCS_TC_MAX[C]
TC_PV_INT
Radc_SET_Adj_MIN[K]
Radc_SET_DISP_Adj_MIN[K]
TC_SET_OUT_MAX[Y]
TC_SET_OUT_MAX[M]
TC_SET_OUT_MAX[C]
TC_SET_INIT
10. dC131 (NVM) after the ATC Sensor is implemented.
11.Check that the following dC131 values have been added according to the ATC Sensor
implementation. NVM are noted if values are judgements or result readings to clarify
some NVM are readings and may vary.
Chain-Link
NVM
No.
Designation
775-731
ATC_CTRL_SW
775-736
TC_Flag1
1/05
3-44
manuals4you.com
manuals4you.com
Table 3
Chain
Link
775
825
775
826
775
827
775
829
775
830
775
831
775
839
775
840
775
850
775
859
775
860
775
874
775
875
775
876
775
896
775
914
775
924
775
966
775
967
775
968
775
991
Table 4
Initial
Value
Set Range
Meaning
1
0~65535
ATC Control Switch 1=ON,
0=OFF
0
0~65535
Calibration Control of the
ATC Sensor for M/C to M/C
variation
1: Execution of the TRC CON
+ Diag.
0: TRC CONT + MINISET by
ATC
DocuColor 12/DCCS50
SET value
15
15
15
20
20
20
8
8
494
10
8
592
592
592
4
100
100
300
300
300
205
Reissue