10-366 Heat Roll Control Thermistor Overheat Failure RAP

The Heat Roll Control Thermistor detected a temperature in excess of 230° C (446° F) on the
Heat Roll.
NOTE: This status code is stored in NVM location 777-160 and cannot be reset by Power Off/
Power On. To reset this code, enter Diagnostics and change the value in NVM location 777-
160 Fuser Over heating Failure from 1 to 0.
Initial Actions
Refer to BSD 10.2 and 10.12 for the following procedure.
Open the Drawer and extend it to the service position. Perform the following:
Remove the Oil Cartridge
(PL
8.1).
Remove the Front Cover
(PL
8.1).
Remove the Top Cover
(PL
8.2).
Check the Heat Roll Control Thermistor for cleanliness, damage and excessive wear at
the point where the Thermistor contacts the Heat Roll. If the surface of the Thermistor is
worn, replace the Heat Roll Control Thermistor
Roll for excessive wear due to the Thermistor. Replace the Heat Roll if necessary
8.3).
Procedure
NOTE: Prior to replacing a component, disconnect the connectors to the component (Heat Roll
Control Thermistor and IOT Drive PWB). Check the connectors for broken, bent and dirty pins.
disconnect and reconnect the connectors several times to remove contaminants due to oxida-
tion.
Ensure NVM location 777-160 is reset to 0. Switch off the power. Cheat the Front Door Inter-
lock Switch. Disconnect
P/J171
on the Heat Roll Control Thermistor. The resistance of the
Thermistor should be in the range of 0.78K Ohms when hot, to 150K Ohms when cool (room
temperature). The resistance is in specification.
Y
N
Replace the Heat Roll Control Thermistor
Reconnect the connector. Close the Drawer. Switch on the power. The
declared immediately after self-test completes.
Y
N
Switch off the power. Check the voltage at P/J105-4 on the SSR and GND. Switch on the
power. There is 0 VDC present when self-test completes.
Y
N
The voltage at P/J105-4 increases to approximately +4.3 VDC within 12 min-
utes.
Y
N
Replace the IOT Drive PWB
The Heater Rod remains illuminated while P/J105-4 still reads approximately
+4.3 VDC.
A
B
Status Indicator RAPs
10-366 Heat Roll Control Thermistor Overheat Failure
(PL
8.4). Inspect the surface of the Heat
(PL
8.4).
10-366
fault
(PL
9.2).
A
B
Y
N
This indicates that the problem is intermittent. Replace the Heat Roll Control
Thermistor
(PL
Replace the SSR
(PL
Go to
Flag 9 (Flag 19
w/
TAG
to ground. If OK, replace the IOT Drive PWB
Go to
Flag 3
on BSD 10.2 and check for a short circuit to ground between P/J171-1 and
J413A-7 If OK, replace the Heat Roll Control Thermistor
replace the IOT Drive PWB
(PL
(PL
is
1/05
2-160
manuals4you.com
manuals4you.com
8.4).
9.3).
P31) on BSD 10.2 and check the harness for a short circuit
(PL
9.2).
(PL
8.4). If the problem continues,
9.2).