7-600 Tray 5 Adjustment Side Guide Out Of Specified Range Rap - Xerox DocuColor 12/DCCS50 Service Manual

Table of Contents

Advertisement

7-600 Tray 5 Adjustment Side Guide out of specified Range
RAP
The machine detected that Tray 5 Side Guide was outside the specified range.
Initial Actions
Refer to BSD 7.4 for the following procedure.
Check for obstructions in the paper path.
Go to the Control Panel, ensure that Tray 5 Tray Paper Size icon is set to the correct paper
size that is loaded in Tray 5.
Ensure that the NVM location for the Market is the correct country code, 752-001 = 2
Procedure
The paper size being utilized for this procedure matches the paper size selected on the
Touch Screen.
Y
N
Voltage is measured at P/J146-B15 on the IOT PWB and GND on the Tray 5 Size
Sensor.
Y
N
+5 VDC between J703B-7 on the Tray 5 Paper Size Sensor and GND.
Y
N
Go to the
+5 VDC Power (IOT LVPS)
Go to
Flag 1
and
Flag 2
on BSD 7.4 and check the harness for an open circuit or
short to GND. If the harness is OK, replace the Tray 5 Size Sensor
Go to
Flag 2
and
Flag 3
on BSD 7.4 and check the harnesses for an open circuit or short
to GND. If the harness is OK, replace the IOT Drive PWB
Check/Replace the following parts in the order listed until the problem is resolved. Replace any
parts that are worn, binding, or missing.
Spring
(PL
2.5)
Link
(PL
2.5)
Tray 5 Assembly
(PL
2.9)
Status Indicator RAPs
RAP.
(PL
2.13).
(PL
9.2).