7-600 Tray 5 Adjustment Side Guide out of specified Range
RAP
The machine detected that Tray 5 Side Guide was outside the specified range.
Initial Actions
•
Refer to BSD 7.4 for the following procedure.
•
Check for obstructions in the paper path.
•
Go to the Control Panel, ensure that Tray 5 Tray Paper Size icon is set to the correct paper
size that is loaded in Tray 5.
•
Ensure that the NVM location for the Market is the correct country code, 752-001 = 2
Procedure
The paper size being utilized for this procedure matches the paper size selected on the
Touch Screen.
Y
N
Voltage is measured at P/J146-B15 on the IOT PWB and GND on the Tray 5 Size
Sensor.
Y
N
+5 VDC between J703B-7 on the Tray 5 Paper Size Sensor and GND.
Y
N
Go to the
+5 VDC Power (IOT LVPS)
Go to
Flag 1
and
Flag 2
on BSD 7.4 and check the harness for an open circuit or
short to GND. If the harness is OK, replace the Tray 5 Size Sensor
Go to
Flag 2
and
Flag 3
on BSD 7.4 and check the harnesses for an open circuit or short
to GND. If the harness is OK, replace the IOT Drive PWB
Check/Replace the following parts in the order listed until the problem is resolved. Replace any
parts that are worn, binding, or missing.
•
Spring
(PL
2.5)
•
Link
(PL
2.5)
•
Tray 5 Assembly
(PL
2.9)
Status Indicator RAPs
RAP.
(PL
2.13).