6-620 Reflection Rate Failure RAP
The Control Logic has detected that the measured reflective rate for each color is out of the
specific range.
Initial Actions
•
Refer to BSD 6.1 and BSD 6.7 in the following procedure:
•
Ensure that the Exposure Lamp Light Path is not blocked or dirty.
Procedure
PO/PO the machine. If the Fault continues go to the
Status Indicator RAPs
6-620 Reflection Rate Failure RAP
6-371 Exposure Lamp Fail
RAP.
manuals4you.com
manuals4you.com
1/05
2-62
Reissue
DocuColor 12/DCCS50