Xerox DocuColor 12/DCCS50 Service Manual page 731

Table of Contents

Advertisement

Table 1 PH NVM List (761)
Chain-
Link
Name
Default
761-054 ADJUST PRE
0
FEED STOP POSI-
TION(TRAY 1
NUDGER ROLL)
761-055 ADJUST PRE
0
FEED STOP POSI-
TION(TRAY 2
NUDGER ROLL)
761-056 ADJUST PRE
0
FEED STOP POSI-
TION(TRAY 3
NUDGER ROLL)
761-057 ADJUST PRE
0
FEED STOP POSI-
TION(TRAY 4
NUDGER ROLL)
761-058 FUSER ENTRANS
1
SENSOR ON JAM
TIMER SELECT
761-061 ADJUST INVERT
101
MOTOR STOP
POSITION(FROM
FUSER EXIT SEN-
SOR OFF)
761-062 INVERT MOTOR
55
ON TIMING(FACE
DOWN MODE)
Reissue
DocuColor 12/DCCS50
Range
Description
0-31
Time from #1 Feed Out SNR ON to #1
Nudger Roll OFF (PRE Feed stop position
- Adjustment)
Default=0ms
Range=0-62ms (0-31)
Unit=2ms/step
Default DATA=0 (2ms RTMR)
0-39
Time from #2 Feed Out SNR ON to #2
Nudger Roll OFF (PRE Feed stop position
- Adjustment)
Default=0ms
Range=0-78ms (0-39)
Unit=2ms/step
Default DATA=0 (2ms RTMR)
0-39
Time from #2 Feed Out SNR ON to #2
Nudger Roll OFF (PRE Feed stop position
- Adjustment)
Default=0ms
Range=0-78ms (0-39)
Unit=2ms/step
Default DATA=0 (2ms RTMR)
0-39
Time from #2 Feed Out SNR ON to #2
Nudger Roll OFF (PRE Feed stop position
- Adjustment)
Default=0ms
Range=0-78ms (0-39)
Unit=2ms/step
Default DATA=0 (2ms RTMR)
None
Switches the Fuser Entrance Sensor On
Jam Timer
0:PM1
Non 0: PM2 or later
91-121
Time from Fuser Exit SNR OFF to Invert
Motor OFF (Exit Invert Point stop position
- Adjustment)
Default=202ms
Range=182.-242ms (91-121)
Unit=2.ms/step
40-70
Time from Invert Motor OFF to Invert
Motor ON (Exit Invert Point stop time)
Default=110ms
Range=80-140ms (40-70)
Unit=2ms/step
Table 1 PH NVM List (761)
Chain-
Link
Name
Default
761-063 INVERT MOTOR
51
OFF TIM-
ING(DUPLEX
MODE)
761-064 INVERT MOTOR
328
ON TIM-
ING(DUPLEX
MODE:PITCH
1200ms ONLY)
761-065 INVERT MOTOR
426
ON TIM-
ING(DUPLEX
MODE: PITCH
2400ms ONLY)
761-066 INVERT MOTOR
395
ON TIM-
ING(DUPLEX
MODE: PITCH
2083ms ONLY)
1/05
6-51
Range
Description
38-68
Time from Invert Path SNR OFF to Invert
Motor OFF (Duplex Invert Point stop posi-
tion - Adjustment)
Default=102ms
Range=76-136ms (38-68)
Unit=2ms/step
325-331 Time from Registration Motor ON using
Pitch 1200ms Duplex(*1) to Invert Motor
ON (Duplex inversion start timing)
Default=3280ms
Range=3250-3310ms (±30ms) (325-
331)
Unit=10ms/step
Default DATA=3280 (10ms RTMR)
(*1)LETL, A4L, B5L B/W, 4C MODE
423-429 Time from Registration Motor ON using
Pitch 2400ms Duplex(*2) to Invert Motor
ON (Duplex inversion start timing)
Default=4260ms
Range=4230-4290ms (±30ms) (423-
429)
Unit=10ms/step
Default DATA=4260 (10ms RTMR)
(*2) B/W Mode except LETL, A4L, B5L
and B4S, and, 4C Mode except LETL,
A4L and B5L
392-398 Time from Registration Motor ON using
Pitch 2083ms Single Leaf Duplex(*3) to
Invert Motor ON (Duplex inversion start
timing)
Default=3950ms
Range=3920-3980ms (±30ms) (392-
398)
Unit=10ms/step
Default DATA=3950 (10ms RTMR)
(*3)B4S B/W MODE
General Procedures
dC131PH NVM List (761)

Advertisement

Table of Contents
loading

Table of Contents