A
B
Connect the meter from P/J422A-9 on the IOT PWB to GND. Manually move the Stacker
Tray toward the rear until it stops, and then toward the front, until it stops. The voltage at
P/J422A-9 goes from than +5.0 VDC when the tray is to the front, to less than +1.0
VDC when the tray is moved off the front position.
Y
N
Go to
Flag 1
and
Flag 2
on BSD 10.11 and check the harness for an open circuit. If
the harness is good, replace the OCT Offset Home Sensor
Replace the IOT Drive PWB
(PL
9.2).
Enter dC330 010-299 OCT Position Sensor. Press Start. Enter dC330 010-086 Offset Motor
Forward. Press Start. Enter dC330 010-085 Offset Motor Reverse. Press Start. The
play changes from L to H to L.
Y
N
The display indicates a constant H.
Y
N
Go to
Flag 3
on BSD 10.11 and check the harness for a short circuit. If the harness is
good, replace the OCT Offset Position Sensor
Connect the meter from P/J422A-8 on the IOT PWB to GND. Manually move the Stacker
Tray toward the rear until it stops, and then toward the front, until it stops. The voltage at
P/J422A-8 goes from less than +1.0 VDC when the tray is to the front, to +5.0 VDC
when the tray is moved to the rear position.
Y
N
Go to
Flag 3
and
Flag 4
on BSD 10.11 and check the harness for an open circuit. If
the harness is good, replace the OCT Offset Position Sensor
Replace the IOT Drive PWB
(PL
9.2).
Check for obvious damage, missing and/or broken Offset Motor gear assemblies.
Reissue
DocuColor 12/DCCS50
(PL
14.1).
dis-
(PL
14.1).
(PL
14.1).
1/05
2-153

10-300 Inverter Cover Open RAP

The Inverter Cover is detected open.
Initial Actions
Refer to BSD 10.8 and 10.12 for the following procedure.
Check for the following:
Open and close the Inverter Cover. While physically pushing on the Inverter Cover, switch
the power off then on. If the Fault Code does not appear, check Inverter Cover latch and
alignment for damaged parts.
Ensure that connectors
P/J412A
and
and the Inverter Cover Switch and there are no obvious crimped or broken wires.
Procedure
Enter dC330 010-300 Inverter Cover Interlock. Open the Inverter Cover. Manually actuate the
Inverter Cover Switch. The display changes from H to L when the switch is actuated.
Y
N
Connect the meter from P/J412A-11 on the IOT Drive PWB to GND. Manually actuate the
Inverter Cover Switch. The voltage at P/J412A-11 goes from +5 VDC to less than +1.0
VDC when the switch is manually actuated.
Y
N
Go to
Flag 3
on BSD 10.8. Check the harness for an open circuit. If the harness is
good, replace the Inverter Cover Switch
Replace the IOT Drive PWB
(PL
9.2).
If the fault code is present and can not be cleared, replace the IOT Drive PWB
fault code is not present and is occurring intermittently, go to
harness for an intermittent open circuit. If the harness is OK, replace the Inverter Cover Switch
(PL
2.24). If the problem continues, replace the IOT Drive PWB