Y
N
Replace the Pre IPS PWB
(PL
3.5).
+ 5VDC is measured at P/J523-3 and GND on the Driver PWB.
Y
N
Go to
Flag 4
on BSD 6.1 and check the wire for an open or short. If the wire is OK, replace
the IPS Fan
(PL
3.2).
Go to
Flag 4
on BSD 6.1 and check the wires for an open or short circuit. If the wires are OK,
replace the IIT Driver PWB
(PL
3.2).
Reissue
DocuColor 12/DCCS50
6-360 Carriage Position Failure RAP