8-306 Drawer Interlock Open RAP

The Drawer Interlock is detected open.
Initial Actions
Refer to BSD 1.4 and BSD 8.10 for the following procedure.
Procedure
Enter dC330 008-306 Drawer Interlock Switch. Press Start. Open, then close, the Drawer.
The display changes from H when the Drawer is open to L when the Drawer is closed.
Y
N
Connect the meter from P/J419B-18 on the IOT Drive PWB to machine frame. Open,
then close, the Drawer. The voltage at
Drawer is open to less than +1.0 VDC when the Drawer is closed.
Y
N
Connect the meter from P/J11A-3 on the AC Driver PWB to machine frame. Open,
then close, the Drawer. The voltage at P/J11A-3 goes from +5 VDC when the
Drawer is open to less than +1.0 VDC when the Drawer is closed.
Y
N
Connect the meter from P/J14-8 on the AC Driver PWB to machine frame.
Open, then close, the Drawer. The voltage at P/J14-8 goes from less than
1.0 VDC when the Drawer is open to +5.0 VDC when the Drawer is closed.
Y
N
There is + 5 VDC from P/J19-4 on the AC Drive PWB to machine
frame.
Y
N
Replace the AC Driver PWB
Go to
Flag 7
on BSD 1.4 and check the harness for an open circuit. If the
harness is good, replace the Drawer Interlock Switch
Replace the AC Driver PWB
Go to
Flag 6
on BSD 1.4 and check the harness for an open circuit.
Replace the IOT Drive PWB
(PL
9.2).
If the fault code is present and can not be cleared, replace the IOT Drive PWB
fault code is not present and is occurring intermittently, go to
harness for an intermittent open circuit. If the harness is OK, go to
check the wire for an intermittent open or short circuit. If the harness is good, replace the
Drawer Interlock Switch
(PL
2.18). If the problem continues, replace the AC Driver PWB
9.3). If the problem still continues, replace the IOT Drive PWB
Status Indicator RAPs
8-306 Drawer Interlock Open RAP, Main Motor 2 RAP
P/J419B-18 goes from +5 VDC when the
(PL
9.3).
(PL
2.18).
(PL
9.3).
(PL
9.2). If the
Flag 6
on BSD 1.4 and check the
Flag 7
on BSD 1.4 and
(PL
9.2).
Main Motor 2 RAP
Main Motor 2 is inoperative.
Initial Actions
Refer to BSD 8.9 for the following procedure.
Procedure
Enter dC330 008-043 Main Motor 2. Press Start and Stop several times. Main Motor 2 ener-
gizes and deenergizes.
Y
N
Press Stop. +24 VDC is measured between P/J414B-3, 4, 5, 6 on the IOT Drive PWB
and machine frame.
Y
N
+24 VDC is measured between P/J414B-1 on the IOT Drive PWB and machine
frame.
Y
N
Replace the IOT Drive PWB
Go to
Flag 1
and
Flag 2
harness and connectors are OK, replace Main Motor 2
Press Start. The voltage at P/J414B-3, 4, 5, 6 on the IOT Drive PWB goes to approx-
imately +23 VDC.
Y
N
Replace the IOT Drive PWB
Replace Main Motor 2 Motor
If the problem is occurring intermittently, go to
ness for an intermittent open circuit. If the harness is good, replace the Main Motor 2
If the problem continues, replace Main Motor 2
the IOT Drive PWB
(PL
9.2).
(PL
1/05
2-104
manuals4you.com
manuals4you.com
(PL
9.2).
on BSD 8.9 and check the harness and connectors. If the
(PL
1.5).
(PL
9.2).
(PL
1.5).
Flag 1
and
Flag 2
on BSD 8.9 and check the har-
(PL
1.5). If the problem still continues, replace
DocuColor 12/DCCS50
(PL
1.5).
Reissue