Xerox DocuColor 12/DCCS50 Service Manual page 319

Table of Contents

Advertisement

Chain-Link
NVM
Initial
No.
Designation
Value
ATC SENSORS RESULT JUDGMENT OF TC (OK or NG, see step 4)
Chain-Link
NVM
Initial
No.
Designation
Value
775-741
TC_OFFSET_OU
1
T_jd
775-742
TC_Ref_OUT_jd
1
775-743
TC_OUT_jd[Y]
1
775-744
TC_OUT_jd[M]
1
775-745
TC_OUT_jd[C]
1
775-746
TC_Ref_OPEN_
1
OUT_jd
775-747
TC_SET_OUT_jd
1
[Y]
775-748
TC_SET_OUT_jd
1
[M]
775-749
TC_SET_OUT_jd
1
[C]
775-750
TC_SET_ALL_jd
1
NVM COUNTER FOR TC MEASUREMENT FAILURE. (see Appendix 3c)
Chain-Link
NVM
Initial
No.
Designation
Value
775-751
TC_OFFSET_OU
0
T_Fail
Reissue
DocuColor 12/DCCS50
Table 4
Set Range
Meaning
0~65535
Color Selection for ATC Con-
trol
1: YMC (initial value) 2: only
Y, 3: only M, 4: only C, 5: only
YM, 6: only YC, 7: only MC
Table 5
Set Range
Meaning
0~65535
Judgment of TCOFFSET out-
put (1: OK, 0:NG)
0~65535
Judgement of TC reference
plane measurement (1: OK,
0:NG)
0~65535
Judgement of measured TC
value (1: OK, 0:NG) [Y]
0~65535
Judgement of measured TC
value (1: OK, 0:NG) [M]
0~65535
Judgement of measured TC
value (1: OK, 0:NG) [C]
0~65535
Judgement of measured TC
value with shutter open (1:
OK, 0:NG)
0~65535
Judgement of measured TC
value at Diag setup (1: OK,
0:NG) [Y]
0~65535
Judgement of measured TC
value at Diag setup (1: OK,
0:NG) [M]
0~65535
Judgement of measured TC
value at Diag setup (1: OK,
0:NG) [C]
0~65535
General judgement of ATC
control (1: OK, 0:NG)
Table 6
Set Range
Meaning
0~65535
Frequency of TCOFFSET
output fail (hidden fail)
Chain-Link
NVM
Initial
No.
Designation
Value
775-752
TC_Ref_OUT_Fai
0
l
775-753
TC_OUT_Fail[Y]
0
775-754
TC_OUT_Fail[M] 0
775-755
TC_OUT_Fail[C]
0
775-756
TC_Ref_OPEN_
0
OUT_Fail
ATC SENSOR TC READING RESULTS. (see value range description detailed in step 8f).
Chain-Link
NVM
Initial
No.
Designation
Value
775-791
TC_OUT_Adj[Y]
200
775-792
TC_OUT_Adj[M]
200
775-793
TC_OUT_Adj[C]
200
775-782
TC_OUT_Daig_A
0
dj
Appendix 1. ATC set-up procedure
1.
Install at least one new developer. The ATC Sensor must be calibrated from new devel-
oper.
2.
Set 775-731 to 1 turns ATC Sensor on. (0 = off).
3.
Confirm NVM 773-266 through 269 are set to 230, 230, 250, 160. (ADC Targets nominal
values).
4.
Set 775-736 to 1. (Value will return to 0 after executing dC922).
5.
Set 775-737 to appropriate value depending on developer material replaced for set-up.
1 = replacement of YMC
2 = replacement of Y
3 = replacement of M
4 = replacement of C
5 = replacement of YM
6 = replacement of YC
7 = replacement of MC
1/05
3-45
Table 6
Set Range
Meaning
0~65535
Frequency of measured TC
value fail with reference
plane (hidden fail)
0~65535
Frequency of measured TC
value fail (hidden fail) [Y]
0~65535
Frequency of measured TC
value fail (hidden fail) [M]
0~65535
Frequency of measured TC
value fail (hidden fail) [C]
0~65535
Frequency of measured TC
value fail with shutter open
(hidden fail)
Table 7
Set Range
Meaning
140 ~ 200
TC output adjustment value
[Y]
140 ~ 200
TC output adjustment value
[M]
140 ~ 200
TC output adjustment value
[C]
140 ~ 200
Adjustment results of TC
measured value at Diag I/O
check
Image Quality
IQ 47 ATC Sensor RAP

Advertisement

Table of Contents
loading

Table of Contents