dC351 NVM Initialize, Save/Restore

Purpose
Save / Restore NVM
This option saves current NVM settings that were changed since the last service call or to
restore the saved NVM settings since the last service call.
Machine Settings
This option saves the machine settings that were changed since the last service call or to
restore the machine settings since the last service call.
Dust Off Reset
Turns all counters back to zero.
NVM Background Read
This option will read/save all NVM locations found in dC131.
Procedure
1.
Enter the Service Diagnostics Mode. Refer to
using the
PWS.
2.
Select Adjustments on the "Service Entry Screen."
3.
Select NVM Init, S/R. The "NVM Initialize Screen (dC301)" is displayed.
4.
Select the NVM Background Processing (dC351) Tab.
5.
Select Reset All HFSI to reset all HFSI counters to zero.
6.
Select Start Background Read to read the NVM settings to be saved/restored.
NOTE: Select Stop Background Read to stop a "Background Read" in progress.
NOTE:
Table 1
list all NVM values read, saved or restored in NVM Background Process-
ing dC351.
7.
Once the Background Read has completed, select Save Current NVM Settings or
Restore NVM Settings.
8.
Once the NVM Settings have been "Saved" or "Restored", select Save Machine Settings
or Restore Machine Settings.
Table 1
Code
Description
702-002
Tools mode information
702-003
Tools mode information
702-004
Tools mode information
702-020
Tools mode information
702-022
Tools mode information
702-057
Document Size 1
702-122
Tools mode information
702-130
Tools mode information
702-168
Tools mode information
710-004
DADF Lead REGI Time Simplex
Reissue
DocuColor 12/DCCS50
Entering the Service Diagnostic Mode
1/05
6-115
Table 1
Code
Description
710-007
L-REGI Pulse Duplex 8.5x11
710-008
L-REGI Pulse Duplex A4 S
710-009
L-REGI Pulse Duplex 8.5x13
715-028
DADF IPS Offset- FS
715-029
REGI ADJ revise VAL-FS
715-091
White Ref Adjustment Coefficient - Red
715-092
White Ref Adjustment Coefficient - Green
715-093
White Ref Adjustment Coefficient - Blue
715-106
HOSEI SCAN
715-107
MB_SCAN
715-110
CCD Calibration Y Patch-R
715-111
CCD Calibration Y Patch-G
715-112
CCD Calibration Y Patch-B
715-113
CCD Calibration M Patch-R
715-114
CCD Calibration M Patch-G
715-115
CCD Calibration M Patch-B
715-116
CCD Calibration C Patch-R
715-117
CCD Calibration C Patch-G
715-118
CCD Calibration C Patch-B
715-119
CCD Calibration K Patch-R
715-120
CCD Calibration C Patch-G
715-121
CCD Calibration C Patch-B
715-125
Platen / DADF Selection
715-132
REGI Revise VAL- SS
715-133
MAG Revise VAL- SS
720-003
LS OFFSET Tray 1
720-004
LS OFFSET Tray 2
720-005
LS OFFSET Tray 3
720-006
LS OFFSET Tray 4
720-007
LS OFFSET Tray 5
720-008
LS OFFSET Duplex
720-018
ERASE LE
720-019
ERASE TE
720-020
ERASE SIDE
730-001
TIS Parameter
730-002
MUC Adj
730-003
MUC Adj for OHP
730-004
MUL M Rate for Y-Y
730-005
MUL M Rate for M-Y
730-006
MUL M Rate for C-Y
730-007
MUL M Rate for Y-M