10-359 Heat Roll Control Thermistor Failure Rap; 10-360 Heat Roll Overheat Thermistor Failure Rap - Xerox DocuColor 12/DCCS50 Service Manual

Table of Contents

Advertisement

10-359 Heat Roll Control Thermistor Failure RAP

The Heat Roll Control Thermistor detected an abnormal resistance value continuously for more
than 1500 msec (Heat Roll Control Thermistor disconnected).
Initial Actions
Refer to BSD 10.2 and 10.12 for the following procedure.
Open the Drawer and extend it to the service position. Perform the following:
Remove the Oil Cartridge
(PL
Remove the Front Cover
(PL
Remove the Top Cover
(PL
8.2).
Check the Heat Roll Control Thermistor for cleanliness, damage and excessive wear at
the point where the Thermistor contacts the Heat Roll. If the surface of the Thermistor is
worn, replace the Heat Roll Control Thermistor
Roll for excessive wear due to the Thermistor. Replace the Heat Roll if necessary
8.3).
Check the Drawer connector
P700B
mating connector on the IOT, and ensure that the mounting plate for the IOT connector is
not bent or misaligned.
Procedure
NOTE: Prior to replacing a component, disconnect the connectors to the component (Heat Roll
Control Thermistor and IOT Drive PWB). Check the connectors for broken, bent and dirty pins.
Disconnect and reconnect the connectors several times to remove contaminants due to oxida-
tion.
Switch the power off. Disconnect
P/J171
resistance between P/J171-1 and P/J171-2 on the Heat Roll Control Thermistor. The resis-
tance of the Thermistor should be in the range of 0.78K Ohms when hot to 150K Ohms when
cool (room temperature). Note the measurement if it is in specification. The resistance of the
Thermistor is in specification.
Y
N
Replace the Heat Roll Control Thermistor
Reconnect
P/J171
to the Heat Roll Control Thermistor. Close the Drawer. Disconnect
J413A
from the IOT Drive PWB. Measure the resistance from P/J413A-13 to P/J413A-7. The
resistance measurement is the same as the measurement noted above (+/- 5%).
Y
N
Go to
Flag 1
and
Flag 3
on BSD 10.2. Check the harness for an open circuit.
Replace the IOT Drive PWB
(PL
9.2).
Reissue
DocuColor 12/DCCS50
8.1).
8.1).
(PL
8.4). Inspect the surface of the Heat
at the rear of the Fuser for damaged pins. Check the
on the Heat Roll Control Thermistor. Measure the
(PL
8.4).

10-360 Heat Roll Overheat Thermistor Failure RAP

The Heat Roll Overheat Thermistor detected an abnormal resistance value continuously for
more than 1500 msec (Heat Roll Overheat Thermistor disconnected).
Initial Actions
Refer to BSD 10.2 and 10.12 for the following procedure.
Open the Drawer and extend it to the service position. Perform the following:
Remove the Oil Cartridge
Remove the Front Cover
Remove the Top Cover
Check the Heat Roll Overheat Thermistor for cleanliness, damage and excessive wear at
the point where the Thermistor contacts the Heat Roll. If the surface of the Thermistor is
worn, replace the Heat Roll Overheat Thermistor
(PL
Roll for excessive wear due to the Thermistor. Replace the Heat Roll if necessary
8.3).
Check the Drawer connector
mating connector on the IOT, and ensure that the mounting plate for the IOT connector is
not bent or misaligned.
Procedure
NOTE: Prior to replacing a component, disconnect the connectors to the component (Heat Roll
Overheat Thermistor and IOT Drive PWB). Check the connectors for broken, bent and dirty
pins. Disconnect and reconnect the connectors several times to remove contaminants due to
oxidation.
Switch the power off. Disconnect
resistance between P/J172-1 and P/J172-2 on the Heat Roll Overheat Thermistor. The resis-
tance of the Thermistor should be in the range of 0.78K Ohms when hot to 150K Ohms when
cool (room temperature). Note the measurement if it is in specification. The resistance of the
Thermistor is in specification.
Y
N
Replace the Heat Roll Overheat Thermistor
P/
Reconnect
P/J172
to the Heat Roll Overheat Thermistor. Close the Drawer. Disconnect
J413A
from the IOT Drive PWB. Measure the resistance from P/J413A-13 to P/J413A-8. The
resistance measurement is the same as the measurement noted above (+/- 5%).
Y
N
Go to
Flag 1
and
Flag 2
on BSD 10.2. Check the harness for an open circuit.
Replace the IOT Drive PWB
(PL
1/05
10-359 Heat Roll Control Thermistor Failure RAP,
2-157
(PL
8.1).
(PL
8.1).
(PL
8.2).
(PL
8.4). Inspect the surface of the Heat
P700B
at the rear of the Fuser for damaged pins. Check the
P/J172
on the Heat Roll Overheat Thermistor. Measure the
(PL
8.4).
9.2).
Status Indicator RAPs
(PL
P/

Advertisement