Dc100 Service Entry - Xerox DocuColor 12/DCCS50 Service Manual

Table of Contents

Advertisement

Table 1 dC Routines
dC Number
Name
920
Developer Unit Check
922
TRC Control/Toner Density Adjust-
ment
923
ProCon PG
924
TRC Adjustment
933
VH/VM Setup
934
ADC/AGC Setup
939
TRC Check PG
945
IIT calibration
(IIT machine only)
General Procedures

dC100 Service Entry

Description
Rotate the Rotary Developer and set
it at the predetermined position.
Measure the grayscale patch by the
ADC sensor. Make the LUT for IOT
TRC correction.
Print the ProCon PG.
Manually fine adjust each color (low/
mid/high density) in PG.
Set VG, VD light amount, Developing
Bias and ASG Bias output.
Execute automatic adjustment of the
ADC Sensor Gain.
Print the TRC Check PG.
1.
Calculate and set the white ref-
erence compensation coeffi-
cient.
2.
Correct the IIT sensitivity varia-
tion.
1/05
6-22
manuals4you.com
manuals4you.com
dC100 Service Entry
When entering Diagnostics, this routine allows you to view faults in progress, Non-Zero Jams
and HFSI items requiring replacement. Service entry allows you to view product information,
such as:
Product Code
Machine Serial Number
Total Copies
Copies since Last Call
IOT Software Version
Procedure
1.
Enter the Service Diagnostics Mode. Refer to
using the
PWS.
2.
Check the HFSI Requiring Replacement.
3.
Check the Non-Zero Jams. Jams that have occurred since the last service exit with the
"Complete Closeout" option selected. Check for any Jams that have a high number of
occurrences.
4.
Check the Faults In Progress. If any faults in progress are displayed, troubleshoot
accordingly.
5.
Select the Refresh button to have the PWS request and receive the latest information on
Total Copies, Copies Since Last Call, Non-Zero Jams or HFSI Requiring Replacement.
Entering the Service Diagnostic Mode
Reissue
DocuColor 12/DCCS50

Advertisement

Table of Contents
loading