Of19-1 Idfe Fault Entry Rap - Xerox DocuColor 12/DCCS50 Service Manual

Table of Contents

Advertisement

OF19-1 IDFE Fault Entry RAP

NOTE: There are two configurations of the IDFE for this machine. They are identifiable by the
Product Code on the ID tag and by the number of Diagnostic LEDs. Early versions have 5
LEDs and are labeled Product Code GL2. Later versions have 6 LEDs and are labeled Product
Code MFY. This RAP applies generically to both. Where differences between the units exist,
the applicable information is followed by the product code for the specific IDFE.
NOTE: Centerware Network Services is the official name for "web client" and "web UI."
NOTE: The IOT does not log or display Integrated Digital Front End (IDFE) fault codes.
This RAP is intended to help analyze the fault code(s), indicated by the LED display on the
IDFE, or by the Configuration Report and to direct the field service representative to the appli-
cable RAP.
Initial Actions
Refer to BSD 16.1.
Fault Indication
Within 10 seconds of Power-On if any of the LEDs on the
IDFE are de-energized or if the Green Power LED is de-
energized.
NOTE: After a PO/PO is performed all LEDs should
energize for approximately 10 seconds. If this does not
occur, perform RAP 19-001.
Red Failure LED is energized continuously.
Amber Heartbeat LED is energized continuously or de-
energized continuously
Amber Heartbeat LED is energizes for 0.5 seconds and
de-energizes for 0.5 seconds.
Red Failure LED energizes for 0.25 seconds and de-
energizes for 2.0 seconds in a continuously repeated
pattern.
Red Failure LED energizes twice in 0.25 second inter-
vals, then de-energizes for 2 seconds. This pattern is
continuously repeated.
Red Failure LED energizes three times in 0.25 second
intervals, then de-energizes for 2 seconds. This pattern
is continuously repeated.
Red Failure LED energizes four times in 0.25 second
intervals, then de-energizes for 2 seconds. This pattern
is continuously repeated.
Reissue
DocuColor 12/DCCS50
Table 1 Power-on Self Tests (GL2)
Fault
Go to RAP:
DC Power Fault
19-001 DC Power Fault RAP
Booting or Hardware Fail-
19-002 BIOS/Self-Test Fault RAP
ure
Software Load Halted
19-003 Hard Disk Fault RAP
Software Running
DDI IOT Failed Internal
19-004 Printer DDI Communication Fault 1 RAP
Loop back Test
DDI IOT Failure, End to
19-005 Printer DDI Communication Fault 2 RAP
End (Cable, IOT or IDFE
Failure)
DDI IOT Failed Internal
19-006 Scanner DDI Communication Fault 1 RAP
Loop back Test
DDI IOT Failure, End to
19-007 Scanner DDI Communication Fault 2 RAP
End (Cable, IOT or IDFE
Failure)
Verify that the DC wire harness connector, P/J 889 is correctly seated into the IDFE.
From your machine log, obtain the Configuration Report and verify that the version of firm-
ware and software for the IDFE and the IOT are compatible.
Procedure (Product Code GL2)
NOTE: Before evaluating the fault indicated by the Diagnostic LEDs, allow 70-180 seconds to
pass for the Diagnostic LEDs to come to a steady state condition after the IDFE has been
switched-on.
NOTE: If more than one fault is detected the first error encountered is the one displayed.
NOTE: If a hard fault is detected during power up, the software boot sequence test stops. If a
soft fault is detected, the Software boot process will continue.
Switch on the power. Observe the IDFE Diagnostic LEDs
self -test. Compare the observations with the Fault Indication descriptions in
Table
2. Refer to
Table 3
for a description of the function of each LED.
1/05
2-227
(Figure
1) as the system performs
Type of Fault Comments
Hard
IDFE does not log or display fault.
Hard
IDFE does not log or display fault.
Hard
IDFE does not log or display fault.
Normal operation when software is run-
ning.
Hard
IDFE does not log or display fault, web UI
remains active
Soft
IDFE does not log or display fault, web UI
remains active
Hard
Printer and web UI remain active
Soft
Printer and web UI remain active
Status Indicator RAPs
OF19-1 IDFE Fault Entry RAP
Table 1
and

Advertisement

Table of Contents
loading

Table of Contents