10-372 Job Complete Pressure Roll Not Ready Rap; 10-373 Job Incomplete Pressure Roll Not Ready Failure Rap - Xerox DocuColor 12/DCCS50 Service Manual

Table of Contents

Advertisement

10-372 Job Complete Pressure Roll Not Ready RAP

The Pressure Roll Lamp was On continuously for 3 minutes after the current job completed,
but the Pressure Roll did not reach operation temperature.
Initial Actions
Refer to BSD 10.2 and 10.12 for the following procedure.
Procedure
Cheat the Front Door Interlock. Switch on the power. Enter dC330 010-031 Pressure Roll
Heater Rod On. Press Start. The Pressure Roll Heater Rod illuminates momentarily.
Y
N
Go to the
OF10-4 Pressure Roll AC Power
Switch off the power. Cheat the Front Door Interlock Switch. Disconnect
Drive PWB. Check the resistance between J413-A13 and J413-A9 of the harness. The resis-
tance should be in the range of 0.78K ohms when the Heat Roll is hot, to 150K ohms when
cool (room temperature). The resistance is within specification.
Y
N
Disconnect
P/J173
on the Pressure Roll Control Thermistor. The resistance should be in
the range of 0.78K ohms when the Roll is hot, to 150K ohms when cool (room tempera-
ture). The resistance is within specification.
Y
N
Replace the P/R Control Thermistor
Go to
Flag 1
and
Flag 4
of BSD 10.2. Check for a loose wire or connector, or an intermit-
tent short circuit to ground.
Check the following:
Check the P/R Control Thermistor for cleanliness, damage and excessive wear at the
point where the Thermistor contacts the Pressure Roll. Ensure that it is installed correctly.
If the surface of the Thermistor is worn, replace the P/R Control Thermistor
Inspect the surface of the Pressure Roll for excessive wear due to the Thermistor.
Replace the Pressure Roll if necessary
If the problem continues, replace the P/R Control Thermistor
replace the IOT Drive PWB
(PL
9.2).
Status Indicator RAPs
10-372 Job Complete Pressure Roll Not Ready RAP,
RAP.
P/J413A
from the IOT
(PL
8.6).
(PL
(PL
8.3).
(PL
8.6). If the fault persists,
10-373 Job Incomplete Pressure Roll Not Ready Failure
RAP
The Pressure Roll declared Not Ready during a job and the Pressure Roll Lamp was On con-
tinuously for 3 minutes after the machine stopped, but the Pressure Roll did not reach opera-
tion temperature.
Initial Actions
Refer to BSD 10.2 and 10.12 for the following procedure.
Procedure
Cheat the Front Door Interlock. Switch on the power. Enter dC330 010-031 Pressure Roll
Heater Rod On. Press Start. The Pressure Roll Heater Rod illuminates momentarily.
Y
N
Go to the
OF10-4 Pressure Roll AC Power
Switch off the power. Cheat the Front Door Interlock Switch. Disconnect
Drive PWB. Check the resistance between J413- A13 and J413-A9 of the harness. The resis-
tance should be in the range of 0.78K ohms when the Heat Roll is hot, to 150K ohms when
cool (room temperature). The resistance is within specification.
Y
N
Disconnect
P/J173
the range of 0.78K ohms when the Roll is hot, to 150K ohms when cool (room tempera-
ture). The resistance is within specification.
Y
N
Replace the P/R Control Thermistor
Go to Go to
Flag 1
intermittent short circuit to ground.
Check the following:
8.6).
Check the P/R Control Thermistor for cleanliness, damage and excessive wear at the
point where the Thermistor contacts the Pressure Roll. Ensure that it is installed correctly.
If the surface of the Thermistor is worn, replace the P/R Control Thermistor
Inspect the surface of the Pressure Roll for excessive wear due to the Thermistor.
Replace the Pressure Roll if necessary
If the problem continues, replace the P/R Control Thermistor
replace the IOT Drive PWB
1/05
2-164
manuals4you.com
manuals4you.com
RAP.
on the Pressure Roll Control Thermistor. The resistance should be in
(PL
8.6).
and
Flag 4
of BSD 10.2. Check for a loose wire or connector, or an
(PL
8.3).
(PL
(PL
9.2).
P/J413A
from the IOT
(PL
8.6).
8.6). If the fault persists,
Reissue
DocuColor 12/DCCS50

Advertisement

Table of Contents
loading