Dc110 Displaying The Cru-Related Data; Dc118 Jam Counter - Xerox DocuColor 12/DCCS50 Service Manual

Table of Contents

Advertisement

dC110 Displaying the CRU-Related Data

Purpose
Displays the Xerographic CRU NVM data (current and previous data items) in a format that can
be easily understood for effective operation.
Procedure
1.
Enter the Service Diagnostics Mode. Refer to
using the
PWS.
2.
Select Adjustments in the Service Entry Screen.
3.
Select Other Adjustments in the Service Entry Screen.
4.
Select Display CRU Related Data (dC110).
5.
The system displays:
a.
The Current-CRU Related Data and the Previous-CRU Related Data.
6.
Scroll the lists to review the displayed Current and Previous CRU Related Data.
7.
Select the Refresh button to have the PWS request and receive the latest information on
CRU-Related Data.
Reissue
DocuColor 12/DCCS50
Entering the Service Diagnostic Mode
1/05
6-23

dC118 Jam Counter

Purpose
Displays the number of occurrences of Jams from time of previous Complete Closeout on ser-
vice exit until present.
The following screen information displays on the Jam Counters Screen:
All Jams
DADF Jams
Paper Jams
Non-Zero Jams
NOTE: This procedure does not count jams detected while in the Service Mode.
Procedure
All Jams
1.
Enter the Service Diagnostics Mode. Refer to
using the
PWS.
2.
Select Maintenance on the Service Entry Screen. dC118 displays as the default screen.
3.
Select All Jams tab (default).
4.
The Diagnostic Screen displays all Fault codes in this category since the last Service Exit
with the Complete Closeout option selected.
DADF Jams
1.
Select Maintenance on the Service Entry Screen. dC118 displays as the default screen.
2.
Select DADF Jams tab.
3.
The Diagnostic Screen displays all DADF Jams that have occurred since the last Service
Exit with the Complete Closeout option selected.
Paper Jam History
1.
Enter the Service Diagnostics Mode. Refer to
using the
PWS.
2.
Select Maintenance on the Service Entry Screen. dC118 displays as the default screen.
3.
Select Paper Jams tab.
4.
The Diagnostic Screen displays all Paper Jams that have occurred since the last Service
Exit with the Complete Closeout option selected.
Non-Zero Jams
1.
Enter the Service Diagnostics Mode. Refer to
using the
PWS.
2.
Select Maintenance on the Service Entry Screen. dC118 displays as the default screen.
3.
Select Non-Zero Jams tab.
4.
The Diagnostic Screen displays all Jams that have occurred since the last Service Exit
with the Complete Closeout option selected.
dC110 Displaying the CRU-Related Data, dC118
Entering the Service Diagnostic Mode
Entering the Service Diagnostic Mode
Entering the Service Diagnostic Mode
General Procedures

Advertisement

Table of Contents
loading

Table of Contents