6-390 Carriage Overrun Fail (Home End) RAP
The IIT Regi (Registration) Sensor detected an overrun during Full Rate return.
Initial Actions
•
Refer to BSD 6.3 and BSD 6.7 in the following procedure.
•
Verify that the IIT Regi Sensor is correctly aligned and free from contamination.
•
Verify that the Full Rate Carriage and Carriage Cables are installed correctly.
•
Check the Full Rate Carriage Assembly for wear, foreign matter, and alignment of the
components.
Procedure
Go to the
6-361 Scan Initialize Regi Sensor Failure
Status Indicator RAPs
6-390 Carriage Overrun Fail (Home End) RAP, 6 391
RAP.
manuals4you.com
manuals4you.com
6 391 Scan Initialize Failure RAP
The IIT Regi (Registration) Sensor Changed to high when the Carriage Initialization Started.
Initial Actions
•
Refer to BSD 6.3 and 6.7 in the following procedure:
•
Ensure that
P/J515
on the Pre IPS PWB is firmly seated.
•
Ensure that
P/J532
on the IIT Regi Sensor is firmly seated.
Procedure
Enter dC330 006-212 Registration Sensor. Press Start. Move the Full Rate Carriage from the
Home position to the full left position. The display changes from High to Low.
Y
N
Go to the
6-361 Scan Initialize Regi Sensor Failure
Move the Full Rate Carriage to the Home Position. The display changes to High.
Y
N
Go to the
6-361 Scan Initialize Regi Sensor Failure
Replace the Pre IPS PWB
(PL
3.5).
1/05
2-60
RAP.
RAP.
Reissue
DocuColor 12/DCCS50