Parallel Data Output

Used in the Following Case
Used when outputting data to external devices such as a programmable controller or a PC via
the parallel interface.
Important
When performing measurements in the ADJUST window, the values are only output when external output is
enabled by the following method during the measurement.
In the Control area, check "Output" in [Test measurement].
When the measurement is executed in the RUN window, output is executed regardless of the external output
setting.
Even if this processing item is not set up in the scene, the overall judgement for the set processing items is still
output via the OR signal from the parallel interface.

Settings (Parallel Data Output)

Set up the output contents with the expression.
Up to 8 expressions including 0 to 7 can be set in each unit.
1.
In the Item Tab area, tap [Setting].
FZ3 Processing Items List Manual
Parallel Data Output