Setting Conditions When a Parallel Output
Unit is Used
This section describes the methods for connecting a Real-time Parallel Output Unit (ZG-
RPD_1) and outputting the measurement value or judgment result at high speed. The
measurement value is converted to 16-bit binary data before it is output.
Assignment of Terminal Block Output
Set the output content for the Real-time Parallel Output Unit.
FUN mode-[I/O]-[RPD]-[OUTPUT]
Setting value
OFF
MEAS
(measurement value)
JUDGE (judgment value) Outputs the judgment result to the Real-time Parallel Output Unit.
Assignment of Tasks
Set the tasks to be output to the Real-time Parallel Output Unit. This setting is enabled
when measurement values are output.
FUN mode-[I/O]-[RPD]-[TASK]
Setting value
TASK1, TASK2, TASK3,
TASK4, TASK5, TASK6,
TASK7, TASK8
ZG User's Manual
Description
Does not output to the Real-time Parallel Output Unit.
Outputs the measured value to the Real-time Parallel Output Unit.
(default value)
When multiple tasks are set, the respective judgment result for all
tasks is output.
The maximum number of tasks that can be set at once is four tasks.
When the number of setup tasks is four or less, select [4TASKs].
When the number of setup tasks is five to eight, select [8TASKs].
Description
The measurement value of the task selected here is output to the
Real-time Parallel Output Unit. (default value: TASK1)
95
I/O Settings