Output Parameters (Shape Search+) - Omron XPECTIA FZ3 User Manual

Vision sensor
Hide thumbs Also See for XPECTIA FZ3:
Table of Contents

Advertisement

Succession level
Search
skipping
2
Level
4.
When the setting has been changed, tap [Measurement] in the Detail area to verify whether
measurements can be made correctly.
5.
Set up the judgement condition.
Setting item
Count
Measure X
Measure Y
Search
angle
Correlation

Output Parameters (Shape Search+)

Specify how to treat the coordinates to be output to the external device as measurement results.This
item can be changed if necessary.Normally, the factory default value will be used.
Important
After setting up the measurement parameters, changing the output parameters will cause measurement results
to vary accordingly.If the output parameters have been changed, re-specify the measurement, too.
1.
Tap [Output parameter] in the Item Tab area.
100
Shape Search+
[0] to 100
[Checked]
Auto
Unchecked
Manual
[3] to 5
Set value
0 to 100
Specify the number of detections to be judged as OK.
-99999.9999
to
Specify the range of X-axis shifting that is judged to be OK.
99999.9999
-99999.9999
to
Specify the range of Y-axis shifting that is judged to be OK.
99999.9999
-180 to 180
Specify the range of angles that are judged to be OK.
Specify the range of correlation values that are judged to be
0 to 100
OK.However, when the correlation value of the measurement result is
0, the judgement result will be NG regardless of the lower limit setting.
Specify the allowable overlapping range to be
detected for detected images.
0: Do not allow overlapping - 100: Allow
overlapping
Specify how many pixels are skipped when
performing a measurement of the measurement
region.
When automatic is selected, the search level is
set automatically.
Description
FZ3 Processing Items List Manual