When PT is selected
Set value
Setting item
[factory
default]
Angle range
[-180 to 180]
1 to 5
Stability
[3]
Deleting a Model
Deletes a registered model.
1.
Select the model from the list and tap [Delete].

Region Setting (Classification)

Use the rectangle to set up the measurement region for [Classification].
1.
In the Item Tab area, tap [Region setting].
2.
Tap [Edit].
The figure setting area is displayed.
3.
Specify the area in which to search for the model.
The rectangle covering the entire screen is set. Adjust the size and position of the rectangle.
4.
Tap [OK].
The area to measure is registered.
FZ3 Processing Items List Manual
This item specifies the rotation angle range for searching.The normal
direction is clockwise.
If lowering stability does not speed up processing, it is likely that many
candidates have been detected.In this case, specify a larger value for
"Candidate level" or "Stab."