Bright Adjust Setting (Camera Image Input Hdr+) - Omron XPECTIA FZ3 User Manual

Vision sensor
Hide thumbs Also See for XPECTIA FZ3:
Table of Contents

Advertisement

Bright Adjust Setting (Camera Image Input HDR+)

This sets how far to track the brightness of the loaded images.
1.
In the Item Tab area, tap [Brightness adjustment].
1
2.
Set each item in the "Bright adjust setting" area.
Item
Brightness
adjustment
Minimum
Adjustment
range
Maximum
Adjustment
range
Adjust bright
ave.
When a check is placed at "Brightness adjustment", the Brightness Adjustment range is
displayed with blue lines in the "Histogram" area.
Change the "Adjust bright ave." and brightness adjust area.
36
Camera Image Input HDR+
Set value
[Factory
default]
If a check is placed at "Brightness adjustment", the image is output
[Unchecked]
with its brightness automatically compensated.This makes it possible
Checked
to obtain images with stable brightness even if the lighting conditions
fluctuate, for example due to interfering light.
0.00 to 20.00
Specify the follow-up brightness minimum value.
[6.00]
0.00 to 20.00
Specify the follow-up brightness maximum value.
[16.00]
0.00 to 20.00
Specify the target for brightness follow-up.Tapping the [Set current
[11.00]
bright] button updates this value.